Seitenansicht 9
Description
3.2 LED display
SCALANCE W770/W730
10 Operating Instructions, 11/2014, C79000-G8976-C325-04
LED
Color
Meaning
L1
Green
Power supply L1.
L2
Green
Power supply L2.
PoE
Green
Power supply using Power over Ethernet.
P1 Green There is a connection via the first Ethernet interface (Link).
Green and yel-
low flashing
alternately
Data transfer via the first Ethernet interface.
P2
Green
There is a connection via the second Ethernet interface (Link).
Green and yel-
low flashing
alternately
Data transfer via the second Ethernet interface.
R1 Green
SCALANCE W774 in access point mode:
The WLAN interface is initialized and ready for operation.
SCALANCE W774 in client mode or SCALANCE W734:
There is a connection via the WLAN interface.
Green and yel-
low flashing
alternately
Data transfer over the WLAN interface.
Green
flashing briefly
SCALANCE W774 in access point mode:
With 802.11h, the channel is scanned for one minute for primary users
before the channel can be used for data traffic.
SCALANCE W774 in client mode or SCALANCE W734:
The client waits for the MAC address due to the setting "Automatic" for
the "MAC mode" parameter and is connected to no access point.
Green
flashing 3 x
short, 1 x long
SCALANCE W774 in client mode or SCALANCE W734:
The client waits for the MAC address due to the setting "Automatic" for
the "MAC mode" parameter and is connected to an access point.
F
Red
An error occurred during operation with the device.
Red
R1 flashing yel-
low at the same
time
A primary user was found on all enabled channels.
P1
R1
Flashing yellow "Flashing" enabled using SIMATIC NET Primary Setup Tool (PST).
Note
Primary user (radar) on all enabled channels
If the device detects a primary user (for example radar signals) on all enabled channels of
the WLAN interface, the LED F
is lit and
R1
flashes. No data traffic is then possible for the
next 30 minutes. After th
is time, the device runs the scan again and checks whether a
primary user still exists. If no primary user is detected, data traffic is possible again.
The wait time of 30 minutes is necessary due to legal requirements and cannot be shortened
even by resta
rting the device.
Seitenansicht 9