Configuring with Web Based Management
5.10 "iFeatures" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
265
Next Channel
The client scans the next channel from its permitted channel list. If an access point is
there, it connects to it. If it does not find an access point on this channel, it scans the
next channel.
Signal Quality Threshold
Can only be edited if "Scanning Mode" "Next Channel" is enabled. The client is given a
minimum signal strength with which the access point must be seen during the scan so
that a connection can be established to it.
The following threshold values exist for the signal strength:
Level
Signal quality in RSSI
Signal quality in %
1
20
40
2
25
50
3
30
60
4 35 70
5
40
80
Procedure
1. Select the "Enable iPCF" option for the required WLAN interface.
2. Select the required cycle time from the "iPCF Cylce Time [ms]" drop-down list.
3. Select for example "All Channels" from the "Scanning Mode"drop-down list.
4. Click the "Set Values" button
You configure the security settings in "Security > WLAN > Basic".