Temperature Sensor
The minimum acceptable air intake temperature is 5 degrees Celsius. If the
temperature falls below 5 degrees, an alarm is generated.
Normal Minimum Value
The current temperature, in degrees Celsius (°C), inside the enclosure of the
module.
Current Value
The maximum acceptable air intake temperature is 50 degrees Celsius. If
the temperature rises above 50 degrees, an alarm is generated.
Normal Maximum Value
Actions
None.
Power Supply
The power supply converts standard AC line voltage and distributes DC power to all components
in its power domain. The power supply is a separate CRU for enclosures containing IOMF2 CRUs.
In DC-powered Telco systems, the power supply units displayed in slots 31 and 32 of the OSM
GUI represent up to 4 Telco Isolating Converters (TICs) in positions A1, A2, B1, and B2. For
information on installing or replacing power components in a Telco system, see the NonStop
S-Series Central Office Server Installation and Service Guide.
Location in OSM Tree:
CRU: System > Group > Module > Power Supply
Slot Location:
CRU: Power supply CRUs are located in slots 31 and 32 of enclosures containing IOMF2 CRUs.
Example: Power Supply (1.1.31)
Attributes
Power Supply
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Service State
Physical
Identifies the manufacturer of the component.Manufacturer
The state of the power supply CRU as known to the operating system on the
server.
Values
Power State
NOTE: Not displayed for an IOMF or NonStop S7000 PMF CRU.
Logical
The initial state of the power supply component at the time of discovery.
Values
Enabled State
The state of the component as known to the operating system on the server.
Values
Device State