Desigo
™ PX
System controllers
PXC001.D
PXC001
-E.D
PXA40-RS...
for the integration of third-party devices and systems in Desigo
• Integration platforms and system controllers for third-party devices and
systems via KNX, Modbus, M-Bus and other protocols into the automation
level via BACnet
• System controllers for the integration of Desigo RXB/RXL room controllers
• Native BACnet devices with communication via BACnet/LonTalk or
BACnet/IP
• BTL label (BACnet communications passed the BTL test)
• Comprehensive management and system functions (alarm management,
time scheduling, trends, remote management, access protection etc.)
• Supports operation via local or network-compatible operator units PXM…
CM1N9223en_03
2014-07-08
Building Technologies
Seitenansicht 0
1 2 3 4 5 6 7 8 9 10

Inhaltsverzeichnis

Seite 1 - Building Technologies

s 9223 Desigo™ PX System controllers PXC001.D PXC001-E.D PXA40-RS... for the integration of third-party devices and systems in Desi

Seite 2 - − Access protection

Dimensions 750.258143461538.550.870256271.5133,5149.49044.332.59223M01All dimensions in mm  2014 Siemens Switzerland Ltd Subject to change

Seite 3 - ONWORKS bus, PXC001.D only)

Use • The system controllers support the integration of Desigo RXB/RXL room controllers as well as third-party devices and systems via KNX, Modbus o

Seite 4

Ordering Mechanical design The compact construction enables the devices to be mounted on a standard mounting rail. 1 Plastic housing 2a 2b Front c

Seite 5

The terminal blocks are removable for easy wiring. Communication RS232/RS485: RX (Green) : TX (Yellow) KNX: RX (Green) TX (Yellow) Servi

Seite 6

Mounting The devices can be snapped onto standardized rails. The power supply, LonTalk, RS485 and KNX connections have plug-in screw terminal blocks.

Seite 7

The KNX programming pin is situated next to the KNX terminal block and the KNX tool plug Maintenance The real time clock is backed by a lithium bat

Seite 8 - ONWORKS bus

Technical data General device data Operating voltage AC 24 V ± 20% Rated voltage AC 24 V Safety extra-low voltage SELV or Extra-low voltage PEL

Seite 9 - 1 2 3 4 5

RS485 interface Interface type RS485, (electrically isolated) Baud rate, data bits / stop bit(s), parity As for RS232 (depends on software) Cable

Seite 10 - 10 / 10

Pin assignment Plug-in screw terminal block 1 AC 24 V (G) 2 Ground (G0) 3 Functional earth Plug-in screw terminal bl