OverviewInstallationJob SetupOperationMaintenanceTroubleshootingProLINE-RoadRunnerEnglishPN 096-0226-002Operator’s Guidefor Siemens™CONTENTS
8ProLINE-RoadRunner Operator’s Guide AOperator Menus are visible on the RoadRunner control panel, and can be navigated by using the Up Arrow and Down
9ProLINE-RoadRunner Operator’s Guide AView the Supervisor Menus by inserting a PCMCIA card with supervisor authority.(The menus on this page and the n
10ProLINE-RoadRunner Operator’s Guide ARefer to the previous page for the main menu.NOTE: Programmer Diags are only available with a Diagnostic Adapte
11ProLINE-RoadRunner Operator’s Guide ARefer to the main Supervisor Menu (2 pages back) for orientation.1 Actuation duration is set by the Socket Adap
12ProLINE-RoadRunner Operator’s Guide AWarnings and CautionsCompressed AirPoint air hoses away from body. Always wear approved eye protection.Loud Noi
13 ProLINE-RoadRunner Operator’s Guide AMounting on the Assembly Machine... 12Connecting Power and Air ... 16Connecting the Communications
14ProLINE-RoadRunner Operator’s Guide A2To mount RoadRunner on an assembly machine:1. With the feeder table pulled out, slide the supplied hook around
15 ProLINE-RoadRunner Operator’s Guide A3. Slide RoadRunner under the hook so that its centering teeth engage the pin next to the hook.4. Lower
16ProLINE-RoadRunner Operator’s Guide ATo connect the power and the air:1. Turn the RoadRunner power switch to the Off (0) position.2. Grasp the air h
17 ProLINE-RoadRunner Operator’s Guide A3. Connect to a grounded power source using a cable with a standard IEC 320 plug. RoadRunner accepts pow
Data I/O has made a conscientious effort to ensure that the information in this document is accurate and complete. Data I/O assumes no liability for e
18ProLINE-RoadRunner Operator’s Guide ATo connect the Communications Cable (option):1. Correctly orient the connector (the red dot will be on top) and
19 ProLINE-RoadRunner Operator’s Guide A2. Similarly orient and plug the other end of the cable into the SMT feeder table. Use the socket that c
20ProLINE-RoadRunner Operator’s Guide ATo run the Self-Test:1. Turn the power switch On (I).All the control panel indicator lights will come on. When
21ProLINE-RoadRunner Operator’s Guide AInserting a Job Card ... 22Changing the Precisor ... 24Changing theActuator Plate... 26Changing the Socke
22ProLINE-RoadRunner Operator’s GuideTo run a job, insert a TaskLink job card in the PCMCIA card slot. Use only TYPE I or TYPE II PCMCIA cards. To ins
23ProLINE-RoadRunner Operator’s Guide A NOTE: When fully inserted, the job card extends slightly from the PCMCIA card slot.3. The Card
24ProLINE-RoadRunner Operator’s GuideTo change the precisor:1. Select Job, then End, wait for the blue lamp to light and turn the power Off (0).2. Lif
25ProLINE-RoadRunner Operator’s Guide A4. When inserting the new precisor, make sure that the part number faces up and that the small holes near the p
26ProLINE-RoadRunner Operator’s GuideTo change the Actuator Plate:1. Select Job, then End, wait for the blue lamp to light and turn the power Off (0).
27ProLINE-RoadRunner Operator’s Guide A3. Pull the Actuator Plate to slide it out of the grooved brackets.NOTE: The Actuator Plate must be out to acce
1ProLINE-RoadRunner Operator’s Guide A ProLINE-RoadRunnerfor Siemens... 2Jobs and Statistics... 3External View... 4Internal
28ProLINE-RoadRunner Operator’s GuideTo change the Socket Adapter (with the Actuator Plate removed):1. Make sure the power is Off (0).2. Unscrew the t
29ProLINE-RoadRunner Operator’s Guide A3. Without touching the gold contact surfaces on the bottom of the adapter, lift the adapter free.4. Insert the
30ProLINE-RoadRunner Operator’s GuideIf you have an Adjustable Tape-In Module, you may need to adjust the tape width. Adjustable Tape-In Module only—I
31ProLINE-RoadRunner Operator’s Guide A3. Rotate the 3-Position Spacer with your finger until you read 16, 24 or 32, corresponding to your tape width.
32ProLINE-RoadRunner Operator’s GuideTo load a reel of devices:1. Make sure the reel is correctly installed in the rack of the assembly machine.NOTE:
33ProLINE-RoadRunner Operator’s Guide A5. Thread the cover tape up through the cover tape path and attach it to the Cover TapeTake-Up Reel. Advance th
34ProLINE-RoadRunner Operator’s GuideTo align the tape pockets:1. Select Align Pocket from the Operator Menu.2. Press the Up Arrow button to advance t
35ProLINE-RoadRunner Operator’s Guide ARunning a Job ... 36Pausing or Stopping a Job ... 37Ending a Job ... 38Emptying the Reject Bi
36ProLINE-RoadRunner Operator’s Guide ATo run a job:1. Insert a job card in the PCMCIA card slot.2. Clear the conveyor belt of any unneeded devices.3.
37ProLINE-RoadRunner Operator’s Guide ATo pause at the end of the current operation:1. Press Pause on the control panel.To instantly stop in an emerge
2ProLINE-RoadRunner Operator’s Guide AData I/O is proud to introduce a revolutionary new inline solution for high-volume programming of electronic pro
38ProLINE-RoadRunner Operator’s Guide AWhenever you are going to change job cards, you must first end the current job. To end the current job:1. Press
39ProLINE-RoadRunner Operator’s Guide A3. Clear away excess devices from the conveyor belt. 4. Empty the Reject Bin. (See next heading.)5. Empty the C
40ProLINE-RoadRunner Operator’s Guide ATo empty the Reject Bin:1. Press the Pause button.2. Pull the Reject Bin out by grabbing the finger tab and the
41ProLINE-RoadRunner Operator’s Guide ATo empty the Cover Tape Take-Up Reel:1. Press Pause.2. Cut the cover tape, leaving enough slack to reattach.3.
42ProLINE-RoadRunner Operator’s Guide ATo shut down RoadRunner:1. Press Pause.2. Select End Job from the Job Menu and wait for all devices to be place
43ProLINE-RoadRunner Operator’s Guide A5. Empty the Reject Bin. 6. Remove and empty the Take-Up Reel. (For more, see the previous heading.)7. Remove t
44ProLINE-RoadRunner Operator’s Guide ATo restart RoadRunner after a pause or an emergency stop:1. Turn the Emergency Stop button clockwise to release
45ProLINE-RoadRunner Operator’s Guide ACleaning with Air... 46Cleaning with Alcohol... 47Running the Self-Test... 48MaintenanceCh
46ProLINE-RoadRunner Operator’s Guide ATo prevent dust accumulation, inject compressed air into the following component areas:1. Tape-In Module (weekl
47ProLINE-RoadRunner Operator’s Guide ATo prevent dust and oil accumulations, clean the following component areas with isopropyl alcohol on a lint-fre
3ProLINE-RoadRunner Operator’s Guide ATaskLink™ for Windows® is required to process devices on the ProLINE-RoadRunner.TaskLink allows you to create an
48ProLINE-RoadRunner Operator’s Guide ARun the Self-Test procedure approximately once a week.To run the Self-Test procedure:1. Press Pause.2. Clear al
49ProLINE-RoadRunner Operator’s Guide AViewing Errors... 50Enabling a Socket... 52Clearing Jammed Tape... 53Device Rotation
50ProLINE-RoadRunner Operator’s Guide AViewing ErrorsTo view and correct errors:1. Messages will appear in the keypad display.2. Check the condition—t
51ProLINE-RoadRunner Operator’s Guide AStopCautionMotor Controller not respondingSome common error messages are listed below. For more information see
52ProLINE-RoadRunner Operator’s Guide AIf a socket repeatedly becomes disabled, RoadRunner should be serviced.To re-enable a disabled socket:1. Choose
53ProLINE-RoadRunner Operator’s Guide AIf the tape jams, an error message displays and the blue lamp illuminates.To clear the tape path:1. Press the E
54ProLINE-RoadRunner Operator’s Guide ADevice RotationIf devices rotate excessively on the conveyor belt:1. Press Pause. Wait for all the devices to g
55ProLINE-RoadRunner Operator’s Guide AWorldwideData I/O CorporationShipping address:10525 Willows Road N.E.Redmond, WA USA 98052Mailing address:P.O.
Junk text for correct PDFwww.dataio.com
4ProLINE-RoadRunner Operator’s Guide A1. Power and Air Connections2. Power Switch3. Handhold for lifting4. PCMCIA Card Slot and Eject button5. Control
5ProLINE-RoadRunner Operator’s Guide A1. Cover Tape Take-Up Reel2. Tape-In Module3. PNP Probes, Precisor, and Cover4. Reject Bin5. Socket Adapter, Act
6ProLINE-RoadRunner Operator’s Guide AControl Panel Lights1. Blue - Stop Indicator. User intervention is required, or the unit is paused. (Do not remo
7ProLINE-RoadRunner Operator’s Guide A1. Start - start or resume the chosen job.2. Menu - exit to the previous menu, —or show the next message (deleti
Kommentare zu diesen Handbüchern