Siemens FT2014 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Fernseher & Monitore Siemens FT2014 herunter. Desigo Planning Tool - Intelligent Infrastructure Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Answers for infrastructure.
1
2
4
7
3
5
6
8
11
12
9
10
13
1
2
2
3
4
5
1
2
3
4
5
6
7
8
9
10
Desigo Fire Safety –
control panels for all of your needs
Desigo Fire Safety control panels –
design and possibilities
Management
Station
Desigo CC
Peripheral device
BACnet
TCP/IP/LAN
Remote
access with
Desigo Fire
Safety View
Fire control
panel
FC2025
Fire control
panel
FC2025
Fire terminal
FT2050
Fire terminal
FT2050
Fire control
panel
FC2025
Fire control
panel
FC2005-U2
Order no.:
S54400-A9-A1
Fire control
panel
FC2050
Fire control
panel
FC2050
ASAtechnology
detector
ASAtechnology
detector
Notification
appliance
Notification
appliance
Periphery board FCI2016-U1
– Supports 252 devices
– For FC2025
Order no.: S54400-A55-A1
Periphery board FCI2017-U1
– Supports 504 devices
– For FC2050
Order no.: S54400-A56-A1
Option module (LED)
FCM2023-U2
– Optionally available
Order no.: S54400-C45-A1
Option module (blank)
FCM2022-U2
– Optionally available
Order no.: S54400-C44-A1
SAFEDLINK FN2001-U1
– Network module
Order no.: S54400-A60-A1
Remote display FT2014-U2
– Black
Order no.: S54400-F67-A1
Remote display FT2014-R2
– Red
Order no.: S54400-B75-A1
Remote terminal FT2015-U2
– Incl. key switch, black
Order no.: S54400-F68-A1
Remote terminal FT2015-R2
– Incl. key switch, red
Order no.: S54400-B15-A1
Battery bracket FHA2032-U1
Secures batteries to meet
seismic requirements
Order no.: S54400-B43-A1
RS485 class A module FCA2016-A1
– For serial RS485 circuit
Order no.: S54400-A39-A1
Leased line/city tie module
FCI2020-U1
Can be configured with
the ‘Leased line’ or ‘City tie
functions
Order no.: S54400-A57-A1
Remote peripheral module
FCA2018-U1
– Interface to remote printers
Order no.: S54400-A65-A1
License key FCA2012-U1
Activates the Desigo Fire Safety
View function
Order no.: S54400-P102-A1
NAC expansion FCI2011-U1
Adds notification appliance
circuits
Order no.: S54400-A54-A1
Releasing module XCI2001-U1
Releasing for pre-action/deluge
sprinkler
Order no.: S54400-A69-A1
Fire terminal board FTI2001-A1
- For FT2050 fire terminal
Order no.: S54400-A58-A1
Expansion and networking options FC2025/FC2050
Power supply (170 W)
FP2011-U1
– Incl. connection cable
Order no.: 500-450222
Power supply (300 W)
FP2012-U1
– Incl. connection cable
Order no.: S54400-Z60-A1
Power supply (170 W)
FP2011-U1
– Incl. connection cable
Order no.: 500-450222
Power supply FC2025/FC2050
Power supply FC2005
Back box FHB2001-U1
– 1 HU, black
Order no.: S54400-B47-A1
Back box FHB2001-R1
– 1 HU, red
Order no.: S54400-B47-A2
Back box FHB2002-U1
– 2 HU, black
Order no.: S54400-B48-A1
Back box FHB2002-R1
– 2 HU, red
Oder no.: S54400-B48-A2
Outer door FHD2001-U2
– 1 HU, black
Order no.: S54400-B49-A1
Outer door FHD2001-R2
– 1 HU, red
Order no.: S54400-B49-A2
Outer door FHD2002-U2
– 2 HU, black
– 1 window
Order no.: S54400-B50-A1
Outer door FHD2002-R2
– 2 HU, red
– 1 window
Order no.: S54400-B50-A2
Outer door FHD2003-U2
– 2 HU, black
– 2 windows
Order no.: S54400-B51-A1
Outer door FHD2003-R2
– 2 HU, red
– 2 windows
Order no.: S54400-B51-A2
Inner door FHD2004-U1
– Black
Order no.: S54400-B52-A1
Trim kit FHA2035-U1 and
FHA2035-R1
1HU, black and red
Order no.: S54400-B42-A1 (black)
Order no.: S54400-B44-A2 (red)
Trim kit FHA2036-U1 and
FHA2036-R1
Order no.:
S54400-B41-A1
(black)
Order no.:
S54400-B42-A2
(red)
Housings FC2025/FC2050
System operating units FC2025/FC2050
System operating units FC2005
Expansion options FC2005
Operating unit FCM2018-U2
Order no.: S54400-C40-A1
Operating unit FCM2019-U2
– With LED
Order no.: S54400-C41-A1
Main board and operator unit
FCM901-U2
Interface options for loops,
NACs, relays, aux. power,
communication bus, city tie/
leased line module
System LCD display, LEDs,
control buttons
Order no.: S54433-B100-A1
Leased line/city tie module
FCI2020-U1
– Same as FC2025/FC2050
Order no.: S54400-A57-A1
Remote display FSD901-U2
– Black
Order no.: S54433-C102-A4
Remote terminal FSD901-R2
– Red
Order no.: S54433-C102-A3
Battery bracket FHA901-U1
Secures batteries to meet
seismic requirements
Order no.: S54433-B107-A1
Housings FC2005
Housing FH901-U2
– Black
Order no.: S54433-B103-A1
Housing FH901-R2
– Red
Order no.: S54433-B103-A2
Trim kit FHA902-U1
black
Order no.: S54433-B103-A3
Trim kit FHA902-R1
red
Order no.: S54433-B103-A4
1
Outer door
FHD2002-U2
2 HU, 1 window, black
FHD2002-R2
2 HU, 1 window, red
FHD2003-U2
2 HU, 2 windows, black
FHD2003-R2
2 HU, 2 windows, red
4
Operator
interface
FCM2018-U2
standard operating
unit
FCM2019-U2
operating unit
with LEDs
6
SAFEDLINK
– FN2001-U1
7
Periphery board
FCI2016-U1 252 pt
FCI2017-U1 504 pt
8
Back box
FHB2002-U1
2 HU, black
FHB2002-R1
2 HU, red
2
Clear window
FHD2006-U1
3
Inner door
FHD2004-U1
with opening
11
Power supply
FP2011-U1
170 W, 24 VDC
FP2012-U1
300 W, 24 VDC
12
Battery bracket
FHA2032-U1
9
DACT
– FCA2015-A1
10
Fiber module
(SM and MM)
FN2006-U1
single-mode fiber
FN2007-U1
multi-mode fiber
13
Inner door
FHD2005-U1 solid
5
RS485
– FCA2016-A1
1
Main board and
operator unit
– FCM901-U2
4
Operator
interface
FCM2018-U2
standard operating
unit
FCM2019-U2
operating unit
with LEDs
2
Clear window
FHD2006-U1
1
Outer door
FHD2001-U2
1 HU, black
FHD2001-R2
1 HU, red
3
Inner door
FHD2004-U1
with opening
6
SafeDLink
module
FN2001-U1
5
RS485
FCA2016-A1
2
Housing
With back box,
door, window
FH901-U2
black
FH901-R2
red
8
Back box
FHB2001-U1
1 HU, black
FHB2001-R1
1 HU, red
7
Fire terminal
board
FTI2001-A1
5
City tie
FCI2020-U1
10
Fiber module
(SM and MM)
FN2006-U1
single-mode fiber
FN2007-U1
multi-mode fiber
4
Battery bracket
– FHA901-U1
3
Power supply
FP2011-U1
170 W, 24 VDC
9
DACT
– FCA2015-U1
Desigo
TM
Fire Safety
Planning Tool
FC2025/FC2050 networkable
control panels
FC2005 stand-alone
control panel
FT2050 fire terminal
Remote display
FT2014-U2
Order no.:
S54400-F67-A1
Remote terminal
FT2015-U2
Order no.:
S54400-F68-A1
Remote terminal
FSD901-U2
Order no.:
S54433-C102-A4
Customer network
NAC
NAC
RS485
FCnet/SAFEDLINK
FDnet
FDnet
RS485
growing. For our customers, success is defined by how
well they manage these challenges. Siemens has the
answers.
We are the preferred partner for energy-efficient,
safe, and secure buildings and infrastructure.”
Answers for infrastructure.
Our world is undergoing changes that force us to think
in new ways: demographic change, urbanization, global
warming, and resource shortages. Maximum efficiency
has top priority – and not only where energy is concerned.
In addition, we need to increase comfort for the well-being
of users. Also, our need for safety and security is constantly
www.usa.siemens.com/desigo-fire-safety
The information in this document contains general descriptions of technical options available,
which do not always have to be present in individual cases. The required features should therefore
be specified in each individual case at the time of closing the contract.
All rights reserved. Printed in USA 153-FIS-110
©2011 Siemens Industry, Inc.
Siemens Industry, Inc.
8 Fernwood Road
Florham Park, NJ 07932
Tel (973) 593-2600
Fax (973) 593-6670
110507_Desigo_Fire.indd 1 11/10/11 9:31 AM
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Fire Safety

Answers for infrastructure. 1247356811129101312234512345678910Desigo Fire Safety – control panels for all of your needsDesigo Fire Safety control

Seite 2 - Intelligent technology for

FCnet/SAFEDLINKSiemens owns one of the largest fire test lab-oratories in the world. We conduct live fire behavior tests in eight te

Kommentare zu diesen Handbüchern

Keine Kommentare