8 Available Services by Port
Services Port Number Port Open Port Default
Access
Authorized
Note
TACACS+ TCP/49
(configurable)
Open
(configurable)
Closed Yes
RADIUS UDP/1812
to send
(configurable),
opens random
port to listen to
Open
(configurable)
Closed Yes Only available
through two
management
interfaces.
Remote Syslog UDP/514
(configurable)
Open
(configurable)
Closed No Only available
through two
management
interfaces.
DNP over RawSocket TCP/21001 to
TCP/21016
Open
(configurable)
Closed No
DNPv3 UDP/20000
TCP/20000
UDP Open;
TCP open after
configured first
time - can not be
closed
UDP Open; TCP
Closed
No
RawSocket/Telnet COM UDP/50001 to
UDP/50016
TCP/50001 to
TCP/50016
Open
(configurable)
Closed No
Preemptive RAW Socket TCP/62001 to
TCP/62016
Open
(configurable)
Closed No
TIN UDP/51000
TCP/51000
UDP Open;
TCP open after
configured first
time - can not be
closed
UDP Open; TCP
Closed
No
WIN UDP/52000
TCP/52000
UDP Open;
TCP open after
configured first
time - can not be
closed
UDP Open; TCP
Closed
No
MICROLOK UDP/60000 UDP Open;
TCP open after
configured first
time - can not be
closed
UDP Open; TCP
Closed
No
MirroredBits UDP/61001 to
UDP/61016
Open
(configurable)
Closed No
TCP Modbus (Server) TCP/502 Open Open No Only available
through two
management
interfaces.
TCP Modbus (Switch) TCP/502 Open
(configurable)
Closed No
DHCP, DHCP Agent UDP/67 sending
msg if enabled - if
received, always
come to CPU,
Open Open No