TC35i AT Command Set
4.12 AT^STPB
s
m
obil
e
TC35i_ATC_V02.07 Page 108 of 439 1/30/04
Confidential / Released
Parameter Description
0
(&F)
The parity bit will not be transmitted over the air and will be replaced with 0.
This mode is the default setting if 7E1 or 7O1 is activated with
AT+ICF.
1 In a data connection 8 bits will be transmitted, including the parity bit, i.e. the
parity bit will be properly transmitted over the air. The setting shall be used if
problems are encountered when TC35i is running in the default 7E1 or 7O1
mode enabled with
AT+ICF. In this case, AT^STPB=1 shall be set in addition
to the 7E1 or 7O1 settings selected with
AT+ICF.
<n>
(num)(&W)