16.2 BIOS Setup
SIMATIC IPC427C
128 Operating Instructions, 10/2010, A5E02414743-03
"Boot Options" submenu
Figure 16-5 "Boot Options" submenu
Quick Boot Mode Some hardware tests are skipped to speed up the boot sequence.
The boot sequence is stopped if an error is detected during booting; you
must press F1 to acknowledge.
Never halt on
errors
Booting continues if errors occur
Halt on all errors Booting is stopped if an error is detected
All without
keyboard
Booting is stopped if any error except a keyboard error
occurs
POST errors
All without
kb/smart
Stop at any error, but not with a keyboard or S.M.A.R.T
storage media error.
Diagnostic screen Shows the diagnostics messages on the monitor during booting.