Siemens 680 Betriebsanleitung Seite 62

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 112
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 61
"RF680M" software
9.3 The data editor
SIMATIC RF680M Mobile Reader
60 Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618
9.3 The data editor
Prerequisites for working in the data editor
In order to process tag data, a tag must have been scanned by the SIMATIC RF680M device
and its tag ID must be indicated in the display. See Chapter Scanning RFID tags and their
tag ID (Page 65).
The tran
sponder data can be edited in the editor window in hex, ASCII or decimal format.
You can toggle between the two in the "Tools > Settings" menu. (See Settings (Page 80)).
Interface structure of the data editor
User interface Item Description
Menu bar
Indication of the tag ID
Drop-down list box with the transponder-specific memory
areas (e.g. EPC, TID, USER) that are displayed in the data
field.
Length of the data area (the field can be edited if
"Complete" is not checked)
Data field
The data can be displayed in either Hex, decimal or ASCII
format.
Buttons for processing the tag data:
Scan tag (ID)
Read tag data
Write to the tag
Copy data to another tag
Indication of the tag type
The editor window contains the tag data. The size of the
represented data depends on the tag type.
(Start) address (the field can be edited when "Total" is not
checked)


"Complete" check mark: Indication of the completely
selected memory area; all memory areas of the tag are
always read or written at once, independent of the memory
area currently set.
One memory area of the most recently scanned tag is always shown in the editor. In the
drop-down list box [
], you can select and display the different memory areas of the tag. If
you check "Complete"
, the current memory area will be displayed complete in the editor,
otherwise you can enter values under "Address" [
] and "Length" [⑩] to display the
relevant data area only.
Seitenansicht 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 111 112

Kommentare zu diesen Handbüchern