TC12 General Handbook
666/HB/43100/000 Page 5-17 Issue 9
5.6.4 Configurable options
If no loops are configured for HIOCC then the HIOCC facility will not be enabled.
Note: The default settings below are applied on first time startup or complete OTU reset. Any
alterations made by the handset are maintained across power failures.
Configurable options include thresholds for:-
a) Occupancy alarm threshold, which is used to determine alarm conditions. Handset command
for entry of this value is GHA.
b) Timed zero occupancy. The handset command used to configure this will be GHZ.
c) Smoothed occupancy high value used on alarm detection. The handset command for setting
this is GHV.
d) HIOCC loop input allocation, assigns an input bit for each HIOCC unit. The handset command
for this is GHL.
e) The number of consecutive occupancy samples used to determine if an alarm condition
exists, range 0 to 10. Handset command GHN.
f) The smoothing factor used in calculating the new smoothed occupancy. The handset
command for this is GHF.
g) The fixed clearance threshold is used to determine an alarm clearance condition in the event
that the smoothed occupancy average is at a abnormal level prior to an alarm. It has a
range of 0-100%. The handset command to configure this is GHC.
h) UTC Reply message bits must be set by using the handset command GRL. There will be a
separate bit allocated for each loop monitored by HIOCC. A maximum of 8 reply bits can be
configured for HIOCC.
5.6.5 Instation Test Set
The Instation test set is used to monitor and test the operation of the TC12 system when using
analogue data transmission. It can be used at all the TC12 baud rates (See section 5.1.1) and at
any signal level between 0dBm and -63dBm. There is a pair of headphones connected to the ITS
which allows the user to listen to both control and reply messages.
Whichever mode the ITS is operating in the physical connection to the unit under test does not
change.
There are three modes of operation for the ITS:
5.6.6 Monitor Mode
When the ITS is operating in this mode the operation of any key (except the mode selection key)
has no effect on the data being transmitted between the instation and the OTU.
Connecting the ITS (in this mode) to the OTU or ITU does not cause an error in the data being
transmitted between the instation and the OTU for more than one second.
5.6.7 Instation Mode
In this mode the ITS replaces the computer and the instation equipment. The ITS transmits at one
second intervals to a selected OTU, a control message in accordance with the display setup.