HC15 Hardware Interface Description
3.8 PWR_IND Signal
s
HC15_HD_v01.000 Page 31 of 67 2007-1-19
Confidential / Released
3.8 PWR_IND Signal
PWR_IND notifies the on/off state of the module. High state of PWR_IND indicates that the module is switched
off. The state of PWR_IND immediately changes to low when IGT is pulled low. For state detection an external
pull-up resistor is required.
Figure 12: PWR_IND signal
3.8.1 Network Connectivity Status Signals
Two status signals (STATUS0 and STATUS1) are provided for signaling the module’s connectivity status. Each
signal acts as a current sink and can be used to control externally connected LEDs. For electrical characteristics
see Table 16.
Additional pull up resistors or LED's are required as shown in the below sample circuit for a status LED:
Figure 13: Status LED Circuit (example)
Please ensure that the voltage applied at the status pins does not exceed BATT+.
This status function has to be activated with AT^SLED. For details see the [1].