Getting Started with HC15
3 Using the HC15 Module
s
HC15_startup_v02 Page 18 of 36 2007-2-16
Confidential / Released
3 Using the HC15 Module
The following examples show the basic steps required to register to the network, to select UMTS mode
or GSM mode and to attach to HSDPA or GPRS.
The examples are based on a UICC card provisioned by the German network operator T-Mobile. The
used UICC card is capable of UMTS and GSM and enables the subscriber to switch back and forth
between both networks.
3.1 AT Command Interpreter
AT commands can be entered on two interfaces of the HC15 module:
Siemens HSDPA USB Com Port
Siemens HSDPA USB Modem
Yet, we recommend that the Siemens HSDPA USB Com Port be used for controlling the HC15 mod-
ule, eg. for entering AT commands and receiving URCs, while the Siemens HSDPA USB Modem is
mainly intended for use as a modem. For greater detail refer to [2], especially sections "AT Command
Interpreter" and "Unsolicited Result Code Presentation".
As described in Section 2.6, each interface is assigned a virtual COM port of its own, which enables
accessing the interface from the host application or, accordingly, the . To easily identify both interfaces
you can use the AT^SQPORT command:
If you need to operate the HC15 from both interfaces at a time, bear in mind that both are handled by
the same AT command interpreter. As a result, AT commands entered on both interfaces are not exe-
cuted in parallel but sequentially, one after the other. So, an AT command issued on one interface will
be buffered on this interface to be executed after the other interface has completed processing earlier
AT command(s). The buffered command string is not echoed, but will be indicated when executed.
AT^SQPORT
Application
OK
On the AT command interface, the Siemens
HSDPA USB Com Port is referred to as "Applica-
tion".
AT^SQPORT
Modem
OK
On the AT command interface, the Siemens
HSDPA USB Modem is referred to as "Modem".