Commissioning ProTool/Pro Runtime
5-12
ProTool/Pro Runtime User’s Guide
Release 12/99
Note
S Not all the configured tags are provided in the simulation table. Only referenced
tags are available for the simulation, i.e. only those tags used in the project e.g.
in a screen object.
S Since the simulator can only simulate the project offline, i.e. without a
connection to the PLC, the data formats are converted to internal ProTool/Pro
CS formats. Therefore, PLC-specific data formats cannot be realized.
Simulation table
Figure 5-1 Simulation table (example)
Figure 5-1 illustrates an example of a simulation table. All the settings defined in
this table for simulating the project can be saved in a file. In this case, select
File
→
Save
in the simulator and enter a file name (*.sim).
This means that the project can be simulated again at a later date with saved
settings. A condition for this is that the tags and area pointers to be simulated in the
project have not be altered in the meantime.