Recipes
7-9
ProTool/Pro Runtime User’s Guide
Release 12/99
FunctionNo.
Write data record in the PLC
This button is used to write the current data record values in
the PLC.
Key combinations:
Status bar
The operating unit displays the status of the current operation in this
line, e.g. Downloading.
Note
S If the two options
Synchronize Tags
and
Tags Offline
are activated in the
project, the values from the table are applied when values in the tables and
screens are changed simultaneously.
S If the data record currently being edited in the recipe view is changed in the
background (e.g. by means of a PLC job), the recipe view is not automatically
updated.
Tips on operating the recipe view
S Quick selection of recipes and data records
When the selection field is opened up, enter the first letter of the recipe or data
record to be selected to access the relevant area of long lists, thus speeding up
the selection procedure.
S Edit entries
If the value marked in the recipe view is to be modified, it is initially deleted by
pressing one of the alphanumeric keys. This occurs with regard to all list
elements in Windows. In order to prevent this, proceed as follows:
After selecting the value to be changed, press the Enter key. This clears the
marking.
Move the text cursor to the relevant position by pressing the cursor key or
SHIFT
and cursor key.
Insert the modifications.
Confirm the changes, e.g. by pressing the Enter key.