Function overviewDescriptionSiemens SIP · 200812 Motor Protection / 7SK801212/9Protection functions•Time-overcurrent protection(50, 50N, 51, 51N)•Dire
Siemens SIP · 200812 Motor Protection / 7SK801212/18The relay offers flexibility with reference toits communication to substation automa-tion systems
Siemens SIP · 200812 Motor Protection / 7SK801212/19DNP 3.0 protocolPower utilities use the serial DNP 3.0 (Dis-tributed Network Protocol) for the sta
Siemens SIP · 200812 Motor Protection / 7SK801212/20Typical connectionsnConnection of currentand voltage transformersStandard connectionFor grounded n
Siemens SIP · 200812 Motor Protection / 7SK801212/21Typical connectionsConnection for compensated networksThe figure shows the connection of twophase-
Siemens SIP · 200812 Motor Protection / 7SK801212/22Typical applicationsOverview of connection typesType of network Function Current connection Voltag
Siemens SIP · 200812 Motor Protection / 7SK8012Technical Data page 1Technical dataGeneral unit dataAnalog current inputsRated frequency fN50 or 60 H
Siemens SIP · 200812 Motor Protection / 7SK8012Technical Data page 2Technical dataInsulation tests (cont'd)Impulse voltage test (type test)All
Siemens SIP · 200812 Motor Protection / 7SK8012Technical Data page 3Technical dataUnit design (cont'd)Degree of protectionacc. to EN 60529For e
Siemens SIP · 200812 Motor Protection / 7SK8012Technical Data page 4Technical dataSystem interface (cont'd)Transmission rate Up to 19200 baudBr
Siemens SIP · 200812 Motor Protection / 7SK8012Technical Data page 5Technical dataCold-load pickup/dynamic setting changeControllable functions Time
Siemens SIP · 200812 Motor Protection / 7SK801212/10ApplicationFig. 12/7 Function diagramThe SIPROTEC Compact 7SK80 unit is anumerical protection rela
Siemens SIP · 200812 Motor Protection / 7SK8012Technical Data page 6Technical dataNegative-sequence protection (ANSI 46)Definite-time characteristic
Siemens SIP · 200812 Motor Protection / 7SK8012Technical Data page 7Technical dataRestart inhibit for motors (ANSI 66)Setting rangesMotor starting c
Siemens SIP · 200812 Motor Protection / 7SK8012Technical Data page 8Technical data(Sensitive) ground-fault protection (ANSI 64, 50Ns, 51Ns, 67Ns) (c
Siemens SIP · 200812 Motor Protection / 7SK8012Technical Data page 9Technical dataFlexible protection functions (e.g. ANSI 27, 32, 37, 47, 50, 55, 5
Siemens SIP · 200812 Motor Protection / 7SK8012Technical Data page 10Technical dataLong-term averagesTime window 5, 15, 30 or 60 minutesFrequency of
Siemens SIP · 200812 Motor Protection / 7SK8012Technical Data page 11Technical dataClockTime synchronization Binary input,communicationSetting group
Siemens SIP · 200812 Motor Protection / 7SK801212/23Selection and ordering dataDescription Order No.7SK80 motor protection device 7SK80oo – ooooo – oo
Siemens SIP · 200812 Motor Protection / 7SK801212/24seefollowingpageSelection and ordering dataDescription Order No. Ordercode7SK80 motor protection d
Siemens SIP · 200812 Motor Protection / 7SK801212/25Description Order No.7SK80 motor protection device 7SK80oo – ooooo – o H o 0Designation ANSI No. D
Siemens SIP · 200812 Motor Protection / 7SK801212/26Sample orderPosition Order No. + Order code7SK8051-5EC96-3HD0+L0G6 I/O’s: 3 BI/5 BO, 1 live status
Siemens SIP · 200812 Motor Protection / 7SK801212/11ApplicationANSI No. IEC Protection functions50, 50NI>, I>>, I>>>, IE>, IE>
Siemens SIP · 200812 Motor Protection / 7SK801212/27Connection diagramFig. 12/24 7SK801 connection diagram
Siemens SIP · 200812 Motor Protection / 7SK801212/28Fig. 12/25 7SK802 connection diagramConnection diagram
Siemens SIP · 200812 Motor Protection / 7SK801212/29Connection diagramFig. 12/26 7SK803 connection diagram
Siemens SIP · 200812 Motor Protection / 7SK801212/30Connection diagramFig. 12/27 7SK804 connection diagram
Siemens SIP · 200812 Motor Protection / 7SK801212/31Connection diagramFig. 12/28 7SK805 connection diagram*) The shielding of the connecting cableis c
Siemens SIP · 200812 Motor Protection / 7SK801212/32Connection diagramFig. 12/29 7SK806 connection diagram*) The shielding of the connecting cableis c
Siemens SIP · 200812 Motor Protection / 7SK801212/33Dimension drawings in mm / inchFront viewSide viewRear viewFig. 17/227SJ80/7SK80 protection unitfo
Siemens SIP · 200812 Motor Protection / 7SK801212/12Protection functionsAvailable inverse-time characteristicsCharacteristics acc. to ANSI/IEEE IEC 60
Siemens SIP · 200812 Motor Protection / 7SK801212/13Protection functionsDirectional overcurrent protection, ground(ANSI 67N)Directional ground protect
Siemens SIP · 200812 Motor Protection / 7SK801212/14Protection functionsFlexible protection functionsThe 7SK80 enables the user to easily addup to 20
Siemens SIP · 200812 Motor Protection / 7SK801212/15Protection functionsFig. 12/11nMotor protectionRestart inhibit (ANSI 66/86)If a motor is subjected
Siemens SIP · 200812 Motor Protection / 7SK801212/16Protection functionsnVoltage protectionOvervoltage protection (ANSI 59)The two-element overvoltage
Siemens SIP · 200812 Motor Protection / 7SK801212/17Chatter disableThe chatter disable feature evaluateswhether, in a set period of time, the num-ber