Parameter data records
B.1 Parameter assignment and structure of the parameter data records
Analog Input Module AI 8xU/I HS (6ES7531-7NF10-0AB0)
Manual, 07/2014, A5E03484886-AC
39
Operation of the module behind a PROFIBUS DP interface module
If the module is operated behind a PROFIBUS DP interface module, the parameter data
records 0 and 1 are not read back. You get the diagnostics data records 0 and 1 for the read
back parameter data records 0 and 1. You can find more information in the Interrupts section
of the PROFIBUS DP interface module device manual on the Internet
(http://support.automation.siemens.com/WW/view/en/78324181).
Assignment of data record and channel
For the configuration as a 1 x 8-channel module, the parameters are located in data records
0 to 7 and are assigned as follows:
Data record 0 for channel 0
Data record 1 for channel 1
Data record 6 for channel 6
Data record 7 for channel 7
For configuration 8 x 1-channel, the module has 8 submodules with one channel each. The
parameters for the channel are available in data record 0 and are assigned as follows:
Data record 0 for channel 0 (submodule 1)
Data record 0 for channel 1 (submodule 2)
Data record 0 for channel 6 (submodule 7)
Data record 0 for channel 7 (submodule 8)
Address the respective submodule for data record transfer.