AT Command Set
MC35_ATC_01_V04.00 Page 27 of 238 02.04.2002
2.21 ATS3 Write command line termination character
Read command
ATS3?
Response
<n> OK
Write command
ATS3=<n>
This parameter setting determines the character recognized by TA to terminate
an incoming command line.
Response
OK
Parameter
<n> 000-013-127 command line termination character
Reference
V.25ter
Note
2.22 ATS4 Set response formatting character
Read command
ATS4?
Response
<n> OK
Write command
ATS4=<n>
This parameter setting determines the character generated by the TA for result
code and information text.
Response
OK
Parameter
<n> 000-010-127 response formatting character.
Reference
V.25ter
Note
2.23 ATS5 Write command line editing character
Read command
ATS5?
Response
<n> OK
Write command
ATS5=<n>
This parameter setting determines the character recognized by TA as a request
to delete the immediately preceding character from the command line.
Response
OK
Parameter
<n> 000-008-127 command line editing character
Reference
V.25ter
Note