INSTALLATION
2-9
Trunk Bank Sel: Select the TDM bank to transport ETx traffic. Only
one out of two banks (4 * 32 time-slot bus) can be
chosen for each ETx module.
Object name Available
settings
Description
0: PCM30
Default E1 settings for CAS(PCM30) mode
1: PCM30C Default E1 settings for CAS(PCM30) mode with
CRC option enabled
2: PCM31
Default E1 settings for CCS(PCM31) mode
Load Profile
3: PCM31C
Default E1 settings for CCS(PCM31) mode with
CRC option enabled
Initial
System
Are you sure?
Reinitialize system to factory default (CCS mode). All
user defined parameters will be changed.
[ENTER]=’Yes’, [EXIT]=’No’
Lock
Lock front panel to prevent from unauthorized
changes on configuration
Front Lock
Unlock
Unlock front panel. Password is required to release
the lock.
Input : ----
Step 1: Input administrative password for
authentication
Edit : ----
Step 2: Enter new password
Password Edit
Verify : ----
Step 3: Re-enter new password again for verification
Master
Set the module as the clock source of MARS 9000
system
Clk Source
Mode
Slave Follow timing clock from TDM bus
E1 Ch1
Recover clock from 1
st
E1 port
E1 Ch2
Recover clock from 2
nd
E1 port
System Bus
Follow timing clock from TDM bus
Int
Generate clock signal
Clk Source
Sel
Ext
Follow clock signal from EXT CLK interface
Ch 1,2,3,4
Select bank 1 (TDM bus 1~4) as transport medium.Trunk Bank
Sel
Ch 5,6,7,8
Select bank 2 (TDM bus 5~8) as transport medium.
E1 Connect
Sel
Refer to instruction above
Table 2-3 SYSTEM MANAGE group function