INSTALLATION
2-16
Object name Available
Message
Description
SYSTEM SYNC E1 trunk is synchronized with remote system
NO CARRIER
No signal detected on E1 interface
FAS LOSS
Loss of frame alignment. This indicates E1 link
error and is reported when trunk card received
incorrect Frame Alignment Signal.
CAS LOSS
Failed to synchronize with remote system on
signaling (time slot 16) channel under CAS mode.
This indicates an error on E1 link.
SYNC =
CRC LOSS
CRC error detected on received data. This will
only occur when CRC option is enabled. When
CRC LOSS occurs, E1 link could still work with
lower accuracy, depend on the real error rate.
E1
Follow recovered clock from E1.
‘CONFIG E1’->‘CLK SEL’->‘E1’
INT
Generate timing clock with internal oscillator.
‘CONFIG E1’->‘CLK SEL’->‘INT’
CLK SEL
EXT
Follow external clock from EXT CLOCK
connector
‘CONFIG E1’->‘CLK SEL’->‘EXT’
ON
CRC4 function enabled
‘CONFIG E1’->’CRC’->’ON’
OFF
CRC4 function disabled
‘CONFIG E1’->’CRC’->’OFF’
CRC Set
AUTO
CRC4 semi-auto function enabled
‘CONFIG E1’->’CRC’->’AUTO’
NONE
‘CONFIG E1’->’Alarm Gen’->’None’
AIS
‘CONFIG E1’->’Alarm Gen’->’AIS’
Alarm Gen
Remote Alarm
‘CONFIG E1’->’Alarm Gen’->’RALM’
NONE
‘CONFIG E1’->’E BIT’->’None’E Bit
Auto
‘CONFIG E1’->’E BIT’->’Auto’
CCS
‘CONFIG E1’->’Tx Mode’->’CCS’ (PCM31)Tx Mode
CAS
‘CONFIG E1’->’Tx Mode’->’CAS’ CM30)
CCS
‘CONFIG E1’->’Rx Mode’->’CCS’ (PCM31)
Rx Mode
CAS
‘CONFIG E1’->’Rx Mode’->’CAS’ CM30)
Table 2-6 STATUS group function