Explosion-Proof Housings and Mounts
Explosion-Proof Housings
6-2 © Siemens Building Technologies Group
Type Order No.
FH07C..
Phoenix Explosion-Proof Extruded Aluminium Camera Housings‚
ATEX Certified for IIC Applications
The "Phoenix Explosion-Proof" equipment is ATEX-certified to be used
in potentially hazardous areas where there is a risk of explosion
because flammable gases‚ vapours‚ mists or dusts may be present. The
housing is designed to prevent explosion by containing any heat
sparks‚ or flames generated. This prevents ignition of potentially explo-
sive atmospheres or materials outside the equipment. The housing is
ATEX-certified for use in IIC gas environments (includes hydrogen and
acetylene). The housing is supplied complete with heater & sun shield.
The housing can be factory fitted with a wiper and integral 10 or 17fn
AC Telemetry Receiver.
Siemens will deliver this housing only as a factory pre-built version with
Siemens or customer-supplied camera and lens. Therefore one of the
Phoenix-FIT options must be ordered.
Please note‚ that Siemens cannot supply ATEX IIC Equipment certifi-
cates unless one of the Phoenix-CERT options is ordered with each
housing.
Approval Certification to European ATEX
Directive 94/9/EC. Ex ii 2 GD (EExd
IIC T6)
Colour Body: Polyester Powder Coat
RAL1020 (Yellow).
Endplates: Clear Anodised.
Sunshield: White Polyester Powder
Coat.
Cable entry Internal Terminal Block‚ 4 off 20 mm
x 1.5
Finish Aluminium extrusion (housing
body)‚ aluminium (end caps and
sunshield)
Ambient temperature‚ storage -20° C to +40° C
Heater rating 7 W nominal 25 W max.
Protection rating IP67 BS EN 60 529
FH07C..
FH07C-30
230 V AC ATEX IIC Explosion-Proof Housing
As FH07C.. for technical details‚ but with the following differences:
Power requirements 230 V AC
Usable volume (W x H x D) 114 x 94 x 290 mm
Dimensions (W x H x D) 209 x 186 x 545 mm
Weight 10.0 kg
S24245-C4020-A10
FH07C-30/L
24 V AC ATEX IIC Explosion-Proof Housing
As FH07C.. for technical details‚ but with the following differences:
Power requirements 24 V AC
Usable volume (W x H x D) 114 x 94 x 290 mm
Dimensions (W x H x D) 209 x 186 x 545 mm
Weight 10.0 kg
S24245-C4020-A12