Seitenansicht 137
Matrix Switching Systems
Matrix Switchers
10-6 © Siemens Building Technologies Group
Type Order No.
SIMNEO Preconf..
SIMATRIX NEO Preconfigured
Preconfigured constellations of SIMATRIX NEO. SIMATRIX NEO is a vid-
eo matrix that can be expanded up to a maximum of 224 inputs and 32
outputs using both main and extension chassis. The SIMATRIX NEO is a
space-saving 19-inch complete system in a desktop housing‚ commenc-
ing with a basic configuration of 16 inputs‚ 8 outputs and 32 alarms and
includes an LCD display for diagnostic information. The SIMATRIX NEO
is a freely-parameterisable and universally applicable video matrix
switching system‚ including straight forward setup software for up and
downloading of settings. The application range extends from the pure
matrix function up to event-controlled control alarm receiving centres‚
in conjunction with external alarm contacts or messages for processing
danger‚ alarm and intruder signals. IVM is an optional‚ user-friendly
graphical interface for the SIMATRIX NEO. Operation is possible via the
CKA4820 remote keyboard.
Baud rate 1200-19.200 bit/s
Alarm output relay 1
Control outputs 8 control outputs (open-collector);
max. 30 V‚ max. 50 mA‚ Relay with 2
floating changeover contacts for
common alarm output
Character height 18 screen lines
Character representation White black border
Camera sequences 1 sequence per monitor output‚ 32
defineable cycles
Telemetry RS422‚ RS485‚ TTY
Telemetry control 16 x TTY outputs (20 mA current
loop)
Telemetry control RS485 4 RS485 ports protocols: CCDA‚ SCU‚
SIVIS‚ PELCO-D‚ 16xRJ11
Television standard PAL/CCIR
Distance SCU to SIMATRIX Up to 2 km with 0‚8 mm diameter
Parameterisation PC 1 x V.24 (RS232C)
Keyboard interface 8 x TTY interface (20 mA) with pow-
er supply for external keyboard
(200 mA)‚ RJ12
Video loss detection Full automatic
Field size 12 text lines with 24 character each
Matrix point switching time 80 ms (typical.)‚ 200 ms (max.) (fol-
lowing command input on video
matrix)
OSD Full IBM character set
Internal synchronization
Power requirements 115 D 230 V AC‚ Tolerance: +10 % to
-15 %‚ 50-60 Hz switchable
Power consumption Max. 55 W‚ depending on size
SIMATRIX NEO..