SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure, flow and level
DS III series
for differential pressure and flow
2/113
Siemens FI 01 · 2009
2
Selection and Ordering data Order No.
SITRANS P pressure transmitters
for differential pressure and flow
PN 32/160 (MWP 464/2320 psi)
DS III PA series (PROFIBUS PA) 7 M F 4 4 3 4 -
DS III FF series (FOUNDATION Fieldbus) 7 M F 4 4 3 5 -
7 7 7 7 7
-
7 7 7 7
Measuring cell filling Measuring cell
cleaning
Silicone oil Standard 1
Inert liquid
1)
Grease-free 3
Nominal measuring range
PN 32 (MWP 464 psi)
20 mbar
2)
(8.03 inH
2
O) B
PN 160 (MWP 2320 psi)
60 mbar (24.09 inH
2
O) C
250 mbar (100.4 inH
2
O) D
600 mbar (240.9 inH
2
O) E
1600 mbar (642.4 inH
2
O) F
5 bar (2008 inH
2
O) G
30 bar (435 psi) H
Wetted parts materials
(stainless steel process flanges)
Seal diaphragm Parts of measuring cell
Stainless steel Stainless steel A
Hastelloy Stainless steel B
Hastelloy Hastelloy C
Tantalum
3)
Tantalum E
Monel
3)
Monel H
Gold
3)
Gold L
Version as diaphragm seal
4)
5)
Y
Process connection
Female thread ¼-18 NPT with flange connection
• Sealing screw opposite process connection
- Mounting thread
7
/
16
-20 UNF to EN 61518
2
- Mounting thread M10 to DIN 19213
(only for replacement needs)
0
• Venting on side of process flanges
2)
- Mounting thread
7
/
16
-20 UNF to EN 61518
6
- Mounting thread M10 to DIN 19213
(only for replacement needs)
4
Non-wetted parts materials
Process flange screws Electronics housing
Stainless steel Die-cast aluminium 2
Stainless steel Stainless steel precision
casting
3
Version
• Standard version 1
• International version, English label inscriptions,
documentation in 5 languages on CD
2
Explosion protection
• Without A
• With ATEX, Type of protection:
- "Intrinsic safety (EEx ia)" B
- "Explosion-proof (EEx d)"
6)
D
- "Intrinsic safety and explosion-proof
enclosure (EEx ia + EEx d)"
7)
P
- "n (Zone 2)" (planned) E
- "Intrinsic safety, explosion-proof enclosure
and dust explosion protection (EEx ia +
EEx d + Zone 1D/2D)"
7)
(not for DS III FF)
R
• With FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof
(is + xp)"
6)
N C
Electrical connection / cable entry
• Screwed gland M20x1.5 B
• Screwed gland ½-14 NPT C
• M12 connectors (metal)
8)
F
Display
• Without indicator 0
• Without visible digital indicator (digital indicator
hidden, setting: mA)
} 1
• With visible digital indication 6
With customer-specific digital indication (setting
as specified, Order code "Y21" or required)
7
Factory-mounting of shut-off valves and valve manifolds see page
2/142.
Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
• Sealing plug(s) or sealing screw(s) for the process flanges(s)
1)
For oxygen application, add Order code E10.
2)
Not suitable for connection of remote seal. Position of the top vent valve in
the process flanges (see dimensional drawing).
3)
Only together with max. spans 250, 1600, 5000 and 30000 mbar
(100.4, 240.9, 2008 inH
2
O and 435 psi).
4)
When the manufacture’s certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total
combination is certified here.
5)
Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.
6)
Without cable gland, with blanking plug.
7)
With enclosed cable gland EEx ia and blanking plug.
8)
Cannot be used together with the following types of protection:
"Explosion-proof" and "Intrinsic safety and explosion-proof".
Selection and Ordering data Order No.
SITRANS P pressure transmitters
for differential pressure and flow
PN 32/160 (MWP 464/2320 psi)
DS III PA series (PROFIBUS PA) 7 M F 4 4 3 4 -
DS III FF series (FOUNDATION Fieldbus) 7 M F 4 4 3 5 -
7 7 7 7 7
-