1.5.2 Proactive Commands
1.5.2.1 AT^SSTR Remote-SAT Response – Refresh (1)
Write command
AT^SSTR=1,
<status>
If <cmdDetail> reported by AT^SSTGI was 4, ME is performing a SIM reset.
Therefore a Terminal Response should not be issued.
Response
OK
Parameters
<cmdType> 1 – Proactive command ID, see Table 1
<status> Unsigned Integer, range 0-255
0 Command performed successfully
32 TA currently unable to process command
132 TA currently unable to process command because
screen is busy.
Reference
Siemens
Note
1.5.2.2 AT^SSTR Remote-SAT Response – Set Up Event List (5)
Write command
AT^SSTR=5,
<status>
The TA is acknowledging that the Event list has been set up correctly.
Response
OK
Parameters
<cmdType> 5 – Proactive command ID, see Table 1
<status> Unsigned Integer, range 0-255
0 Command performed successfully
32 TA currently unable to process command
132 TA currently unable to process command because
screen is busy.
Reference
Siemens
Note