Siemens HC15 Spezifikationen Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 234
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
HC15 AT Command Set
1.5 AT Command Syntax
s
HC15_ATC_V01.001 Page 14 of 234 2/16/07
Confidential / Released
1.5 AT Command Syntax
The "AT" or "at" prefix must be set at the beginning of each command line. To terminate a command line enter
<CR>. Commands are usually followed by a response that includes "<CR><LF><response><CR><LF>". Through-
out this document, only the responses are presented,
<CR><LF> are omitted intentionally.
Table 1.4: Types of AT commands and responses
1.5.1 Using Parameters
Optional parameters are enclosed in square brackets. If optional parameters are omitted, the current settings
are used until you change them.
Optional parameters or subparameters can be omitted unless they are followed by other parameters. If you
want to omit a parameter in the middle of a string it must be replaced by a comma. See also example 1.
A parameter value enclosed in square brackets represents the value that will be used if an optional parameter
is omitted. See also example 2.
When the parameter is a character string, e.g. <text> or <number>, the string must be enclosed in quotation
marks, e.g. "Charlie Brown" or "+49030xxxx". Symbols in quotation marks will be recognized as strings.
All spaces will be ignored when using strings without quotaton marks.
It is possible to omit the leading zeros of strings which represent numbers.
If an optional parameter of a V.250 command is omitted, its value is assumed to be 0.
Example 1: Omitting parameters in the middle of a string
AT command type Syntax Function
Test command AT+CXXX=? The mobile equipment returns the list of parameters and value
ranges set with the corresponding Write command or by internal
processes.
Read command AT+CXXX? This command returns the currently set value of the parameter or
parameters.
Write command AT+CXXX=<...> This command sets user-definable parameter values.
Exec(ution) command AT+CXXX The execution command reads non-variable parameters deter-
mined by internal processes in the GSM engine.
AT+CCUG?
Query current setting
+CCUG: 1,10,1
OK
AT+CCUG=,9
Set only the middle parameter
OK
AT+CCUG?
Query new setting
+CCUG: 1,9,1
OK
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 233 234

Kommentare zu diesen Handbüchern