HC15 AT Command Set
5.4 AT^SCSL
s
HC15_ATC_V01.001 Page 66 of 234 2/16/07
Confidential / Released
5.4 AT^SCSL Customer SIM Lock
AT^SCSL is a Siemens defined command especially designed to manage the Customer SIM Lock feature. This
feature allows application manufacturers to lock a mobile to specific operators by activating a Network Person-
alization ("PN"). If the lock is enabled the mobile will accept only SIM cards from the given operators.
The lock is activated by specifying the mobile country codes and mobile networks codes on command line.
The Customer SIM Lock feature is protected by depersonalization key.
Syntax
Parameter Description
“PN“ Network Personalisation (= Customer SIM Lock)
0 Delete programmed SIM lock data and disable the personalization.
Required parameters: <facility>="PN", <action>=0, <password>.
Removing the Customer SIM Lock deletes all <data>, i.e. the entire list of
operators .
1 Program given SIM lock data and activate SIM lock.
Required parameters: <facility>="PN", <action>=1, <password>,
<data>.
2 Request Customer SIM Lock status.
Required parameters: <facility>="PN", <action>=2.
4 Request the depersonalization key, allowed if Customer SIM Lock has not
already been programmed. Otherwise returns error.
Required parameters: <facility>="PN", <action>=4.
Depersonalization key associated with the device. The password is not needed for <action>=2 and
<action>=4.
Data of the allowed network operators.
Each operator code consists of the "Mobile Country Code" MCC and the "Mobile Network Code" MNC, both sep-
arated by a dot, e.g. MCC1.MNC1. If more than one operator is entered on the same line, then a colon must be
set between each operator code, e.g. MCC1.MNC1:MCC2.MNC2:MCC3.MNC3. For example, for the three
Test Command
AT^SCSL=?
Response(s)
OK
Write Command
AT^SCSL=<facility>, <action>[, <password>, <data>]