PROFINET IO functionality
7.3 Access options with PNIO
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Operating instructions, 09/2006, A5E00349864 Release 7
7-11
7.3 Access options with PNIO
Slot functions
The products in the SCALANCE X-200 family have one slot for each switch port. Functions
that cannot be assigned uniquely to a port are assigned to the Device Access Point (slot 0).
Slot 0
Alarms
Data records (4.5)
Device Access Point (DAP)
Interface connection
C-PLUG
Signaling contact and its
setting
Redundant power supply
Slot 1 - 8
Alarms
Data records 200,202
Switch port 1 - 8
Alarm response
Port state
Defining the desired alarm generation response
The alarm properties can be used in three different ways:
1. The user configures exactly the assignment and required properties of the ports. The
disadvantage of this solution is that it requires coordination between the installation and
configuration teams. If the project planner specifies in STEP7 that port 3 cannot be
assigned, the installation engineer must not make any connection errors.
Effect of the button during DataEX.
The port assignment is not stored permanently. A flashing LED indicates to the user
that the button (actuation) is not activated.
Effect of other WEB signaling mechanisms
When the device switches to data transfer mode, the Web signaling mechanisms are
adapted to the PNIO setting. The fault mask is disabled in WEB. The message
"Setting not possible because of PNIO" is displayed.
2. The project engineering settings should be adapted in line with the installation settings
(button actuation). This operating mode can be set with an additional button on the
network component. The project engineer does not stipulate the pin assignment for the
installation engineer. The alarm response is adapted automatically. When a button is
pressed after installation, the network component reads the actual states of the
connections and records them as the desired state. When the button is pressed,
monitoring of the pin assignment is enabled. The actual state when the button is actuated
is stored permanently.
Effect of the button during DataEX
If the device is in data transfer mode AND button actuation is set in the parameters,
the desired response for alarm processing is adapted to the new configuration. The
difference is reported accordingly.
3. The project engineering settings should be adapted in line with the installation settings
(start of DataEX).