Description
2.2 Description of the SCALANCE X-300 product line
SCALANCE X-300
Operating Instructions, 01, A5E01113043
15
Signaling contact
The signaling contact (relay contact) is a floating switch with which error/fault states can be
signaled by breaking the contact.
The signaling contact is connected to a 2-pin plug-in terminal block.
The signaling by the signaling contact is synchronized with the fault LED, in other words, all
errors displayed by this LED (freely configurable) are also signaled on the signaling contact.
If an internal fault occurs, the fault LED lights up and the signaling contact opens.
The connection or disconnection of a communication node on an unmonitored port does not
lead to an error message.
The signaling contact remains activated until the error/fault is eliminated or until the current
status is entered in the fault mask as the new desired status.
2.2.4 Ethernet interfaces electrical ports
2.2.4.1 10Base-T / 100Base-TX
Transmission rate
The transmission rate of the electrical ports is 10 Mbps or as Fast Ethernet ports 100 Mbps.
Transmission mode
The transmission mode for 10Base-T / 100Base-TX is specified in the IEEE 802.3i / IEEE
802.3u standards of the Institute of Electrical and Electronic Engineers.
Autonegotiation (automatic detection of the best transmission modes) is default. The order in
which they are selected is:
100Base-TX full duplex
100Base-TX half duplex
10Base-T full duplex
10Base-T half duplex
Two communication modes are possible:
Half duplex
Two-way alternate transmission mode - it is only possible to either send or receive over
the interfaces at any one time.
Full duplex mode
Two-way simultaneous - both communication partners can send and receive at the same
time.