Planning/Configuring
5.2 LED display
SCALANCE X-300
38 Operating Instructions, 01, A5E01113043
5.2.4 LED display - Fault and Power
Display modes A through C
In display modes A through C, the DM LED is lit as described in the section
Selecting the
display modes
. In these three states, the status of the signaling contact and the presence of
the supply voltages are displayed by the LEDs of the IE Switch X-300.
Figure 5-3 Example of the LED display of the device in DMode A
The following table lists the significance of the three LEDs on the IE Switch X-300 for display
modes A through C:
Label Color Status Meaning
off The IE Switch X-300 has not detected any faults, the
signaling contact is closed.
F
Red on The IE Switch X-300 has detected a fault, the signaling
contact opens.
off Power supply L1 lower than 17 V. L1
Green on Power supply L1 higher than 17 V.
off Power supply L2 lower than 17 V. L2
Green on Power supply L2 higher than 17 V.