Description
2.1 Basic information on Ethernet switching
SCALANCE X-300
8 Operating Instructions, 01, A5E01113043
Technical options (network topologies)
The IE Switches X-300 simplify the expansion of a network regardless of the network
topology.
You can use an IE Switch X-300 in the following network topologies:
Linear structure
Star/tree structure
Ring with redundancy manager
The maximum cable length is 10 km for single mode gigabit transmission. A mixed topology
between IE Switch X-300s and OSMs/ESMs is possible on the optical ports. Mixed operation
in the topology between SCALANCE X308-2 and an OSM over the optical ports is not
possible because the SCALANCE X308-2 only supports gigabit.
Using an IE Switch X-300 as the redundancy manager in a ring with redundancy manager
provides greater availability. If there is an interruption on the connection between these
switches, the IE Switch X-300 used as redundancy manager acts like a switch and in a very
short time creates a line from the ring with redundancy manager. As a result, a functional,
end-to-end structure is restored. For information on this topic, refer to the Configuration
Manual "SIMATIC NET; Industrial Ethernet Switches SCALANCE X-300 SCALANCE X-400."
2.1.1 Linear structure
Functional description
Linear structures can be created with the IE Switches X-300. The cascading depth and total
span of a network are limited only by the signal propagation times of the communication
connections.
Properties of the linear structure
Each IE Switch X-300 communicates over a TP or FO cable with a neighboring Ethernet
switch. Communication is possible over the optical or the electrical ports.