Part Number 667-CC-32900-000 Issue 8 Page 1 of 67
ST900 Family Controller Configuration
Siemens Traffic Controls,
Sopers Lane,
Poole,
Dorset,
BH17 7ER
Document Authorisation
Role Name Function Signed
Prepared
by:
Stephen Thorpe Project Support Engineer
Reviewed
by:
Colin Whipps Technical Support Manager
Authorised
by:
Colin Whipps Technical Support Manager
Document record
Issue
Number
Date Comment/Revision Details
001 12/09/07 Initial release
002 06/06/08 Update draft 001
003 03/02/10 TS005210
004 07/06/10 General Corrections and updates. Updates and
TS005031 (Tactile Upgrade)
TS005048 (250V Tapped Transformer)
TS005118 (Gemini Battery Orientation)
TS005411 (ELV Audible Unit)
005 01/01/11 TS005859 (LED Upgrade)
006 17/01/11 TS005969 Lower fusing LV controller (ST900 LED)
007 10/07/12 TS006646 WiMag
TS006685 30A Modification Kit correction
TS006700 Sect 7.2.3 MDU Controller Fuse change from 10A to 16A
008 03/10/12 TS006700 Update for SLD4
Important Note:
When viewing this document electronically, please be aware that access to any of the related documents,
via the hyperlinks provided, requires server logon.
If you experience problems with any of the links in this Controller Configuration document please contact
Technical Support.
This document is held electronically.
This is an unpublished work, the copyright of which vests in Siemens Plc. All rights reserved.
The information contained herein is the property of Siemens Plc. and is supplied without liability for
errors or omissions. No part may be reproduced or used except as authorised by contract or other
written permission. The copyright and the foregoing restriction on reproduction and use extend to all
media in which the information may be embodied.
Seitenansicht 0
1 2 3 4 5 6 ... 66 67

Inhaltsverzeichnis

Seite 1

Part Number 667-CC-32900-000 Issue 8 Page 1 of 67 ST900 Family Controller Configuration Siemens Traffic Controls, Sopers Lane, Poo

Seite 2

Part Number 667-CC-32900-000 Issue 8 Page 10 of 67 6.2 LSLS, HPU, LPU and Controller Selection 6.2.1 Controller Outercase specific

Seite 3

Part Number 667-CC-32900-000 Issue 8 Page 11 of 67 6.2.2 LSLS Positioning Each LSLS card connects into an LSLS Backplane PCB. The co

Seite 4 - 1 General

Part Number 667-CC-32900-000 Issue 8 Page 12 of 67 6.2.3 HPU Load Distribution and LSLS Connections With reference to the flow char

Seite 5

Part Number 667-CC-32900-000 Issue 8 Page 13 of 67 6.3 Cabinet Back panels Two back panels will be positioned centrally at the rear

Seite 6 - 4 General Parts List

Part Number 667-CC-32900-000 Issue 8 Page 14 of 67 6.4 Master Switch Assembly The Master Switch Assembly forms part of the Outercas

Seite 7 - ST900 Configuration Parts

Part Number 667-CC-32900-000 Issue 8 Page 15 of 67 6.5 Mains Transformer The appropriate transformer is contained with the Outer ca

Seite 8 - ST900 LED Overview

Part Number 667-CC-32900-000 Issue 8 Page 16 of 67 6.6 Manual Panel The Manual Panel is contained within a secure compartment in th

Seite 9 - ST900ELV Outercase Selection

Part Number 667-CC-32900-000 Issue 8 Page 17 of 67 Figure 8 Case 1 – Up to 8 Loop detector PCBs, or up to 4 Loop detector cards and

Seite 10

Part Number 667-CC-32900-000 Issue 8 Page 18 of 67 Case 3 – More than 16 Loop detector cards (No Gemini Fitted) First 16 loop detec

Seite 11

Part Number 667-CC-32900-000 Issue 8 Page 19 of 67 First 12 loop detector cards go in main rack as described Case 2. Further loop de

Seite 12

Part Number 667-CC-32900-000 Issue 8 Page 2 of 67 Contents 1 General ...

Seite 13 - Cabinet Back panels

Part Number 667-CC-32900-000 Issue 8 Page 20 of 67 Figure 12 Communications between CPU PCB and Intelligent Detector Backplanes ar

Seite 14 - Master Switch Assembly

Part Number 667-CC-32900-000 Issue 8 Page 21 of 67 Figure 13 6.7.2 SLD4 Single Detector Backplanes 667/1/15990/003 an

Seite 15 - Mains Transformer

Part Number 667-CC-32900-000 Issue 8 Page 22 of 67 6.8 Serial I/O cards (4-O/P 667/1/32995/002 and 16-O/P 667/1/32995/001) Input O

Seite 16 - Manual Panel

Part Number 667-CC-32900-000 Issue 8 Page 23 of 67 The following section defines the order of allocation for the serial I/O cards st

Seite 17

Part Number 667-CC-32900-000 Issue 8 Page 24 of 67 6.9 Gemini Unit 667/1/32600/ETC This unit is not included in the Outercase order

Seite 18

Part Number 667-CC-32900-000 Issue 8 Page 25 of 67 6.10 WiMag 667/1/47200/000 WiMag is not included in the Outercase ordered from t

Seite 19

Part Number 667-CC-32900-000 Issue 8 Page 26 of 67 The selected POE device should be installed prior to the installation of the WiMa

Seite 20

Part Number 667-CC-32900-000 Issue 8 Page 27 of 67 PHS (PL2 or PL4) PCB at the controller’s Processor PCB. On those occasions when th

Seite 21

Part Number 667-CC-32900-000 Issue 8 Page 28 of 67 6.11 TC12 OTU 667/1/27000/000 The Outstation Transmission Unit, based around th

Seite 22 - 667/1/32995/001)

Part Number 667-CC-32900-000 Issue 8 Page 29 of 67 6.11.2 Freestanding TC12 The TC12 can be configured in the ST900ELV as a stand

Seite 23

Part Number 667-CC-32900-000 Issue 8 Page 3 of 67 7 ST900 LV Rules for Hardware Allocation ...

Seite 24 - Gemini Unit 667/1/32600/ETC

Part Number 667-CC-32900-000 Issue 8 Page 30 of 67 6.12 Loop termination PCBs (part of Intelligent Detector BP kit 667/1/32910/000)

Seite 25 - WiMag 667/1/47200/000

Part Number 667-CC-32900-000 Issue 8 Page 31 of 67 Loop Termination PCB 6 allocated to Panel 2, position LT6 Loop Termination PCB 7 a

Seite 26

Part Number 667-CC-32900-000 Issue 8 Page 32 of 67 6.14 Tactile Driver 6.14.1 Non Switched Tactiles 667/7/17390/048 Non Switched ta

Seite 27

Part Number 667-CC-32900-000 Issue 8 Page 33 of 67 6.15 Regulatory Sign Connections 6.15.1 HPU Regulatory Sign Connections 667/1/33

Seite 28 - TC12 OTU 667/1/27000/000

Part Number 667-CC-32900-000 Issue 8 Page 34 of 67 6.15.2 Additional Regulatory Sign Kit 667/1/33070/000 If the 2nd HPU PCB is not

Seite 29 - 6U Rack

Part Number 667-CC-32900-000 Issue 8 Page 35 of 67 Figure 35 Figure 36 Lamp monitoring is performed (if required) by LSLS

Seite 30 - 667/1/32910/000)

Part Number 667-CC-32900-000 Issue 8 Page 36 of 67 6.16 Detector Power and Ancillary Power 6.16.1 HPU Derived Power for Detectors T

Seite 31

Part Number 667-CC-32900-000 Issue 8 Page 37 of 67 6.16.2 Two Amp Ancillary Power Supply 667/1/33075/000 2amps DC RMS On those occa

Seite 32 - Tactile Driver

Part Number 667-CC-32900-000 Issue 8 Page 38 of 67 On those occasions when additional -24 AC power is required, and a second HPU has

Seite 33 - Regulatory Sign Connections

Part Number 667-CC-32900-000 Issue 8 Page 39 of 67 6.17 SDE/SA PCB Kit of Parts 667/27005/000 SDE/SA is an integral facility in th

Seite 34

Part Number 667-CC-32900-000 Issue 8 Page 4 of 67 1 General Purpose and scope of the ST900 Family Controller Configuration This ST

Seite 35

Part Number 667-CC-32900-000 Issue 8 Page 40of 67 7 ST900 LV Rules for Hardware Allocation 7.1 ST900 Outercase Selection With ref

Seite 36

Part Number 667-CC-32900-000 Issue 8 Page 41of 67 Figure 46 Warning! Figure 46 shows a Gemini unit, full configuration details

Seite 37 - – 24VAC

Part Number 667-CC-32900-000 Issue 8 Page 42of 67 7.2 ST900 Rack Assembly The ST900 is configured with a 19 inch swing frame to whi

Seite 38

Part Number 667-CC-32900-000 Issue 8 Page 43of 67 Figure 47 7.2.2 Mains Distribution Unit (MDU) The MDU need not be ordered separ

Seite 39 - Siecom -Bluetooth

Part Number 667-CC-32900-000 Issue 8 Page 44of 67 7.3 Termination Panel With reference to table 6 and figure 48, one Termination Pan

Seite 40 - ST900 Outercase Selection

Part Number 667-CC-32900-000 Issue 8 Page 45of 67 7.4 Master Switch Assembly The Master Switch Assembly forms part of the Outercas

Seite 41

Part Number 667-CC-32900-000 Issue 8 Page 46of 67 On those occasions when a 1.5KVA ST900 Outercase is specified the appropriate trans

Seite 42 - ST900 Rack Assembly

Part Number 667-CC-32900-000 Issue 8 Page 47of 67 7.6 Manual Panel The Manual Panel is contained within a secure compartment in the

Seite 43 - Terminal

Part Number 667-CC-32900-000 Issue 8 Page 48of 67 In the interests of efficient use of cabinet space it may be decided to fit the fir

Seite 44 - Termination Panel

Part Number 667-CC-32900-000 Issue 8 Page 49of 67 protocol relies on addressing techniques to ensure the appropriate information is d

Seite 45 - Dimming Transformer

Part Number 667-CC-32900-000 Issue 8 Page 5 of 67 3 Product Related Documentation Table 2 Document Number Tile 667/HB/32900/000

Seite 46

Part Number 667-CC-32900-000 Issue 8 Page 50of 67 Figure 54 7.7.2 Single Detector Backplanes - 667/1/15990/003 If preferred, Sing

Seite 47

Part Number 667-CC-32900-000 Issue 8 Page 51of 67 7.8 Serial I/O Cards 667/1/32995/001(4 O/P) 667/32995/002(16 O/P) The Serial I

Seite 48

Part Number 667-CC-32900-000 Issue 8 Page 52of 67 Figure 57 show the positioning of the l/O cards when Loop Termination Boards are no

Seite 49

Part Number 667-CC-32900-000 Issue 8 Page 53of 67 7.9 Gemini2 The ST900 Outercase is configured with a 19” Swing Frame and a Rack

Seite 50

Part Number 667-CC-32900-000 Issue 8 Page 54of 67 7.10 WiMag 667/1/47200/000 WiMag is not included in the Outercase ordered from ta

Seite 51

Part Number 667-CC-32900-000 Issue 8 Page 55of 67 Figure 60 Connect a non-POE Ethernet port to the user maintenance Ethernet po

Seite 52

Part Number 667-CC-32900-000 Issue 8 Page 56of 67 the Ethernet ports on the PHS PCB occupied an output port on an Intelligent Detecto

Seite 53

Part Number 667-CC-32900-000 Issue 8 Page 57of 67 7.11 TC 12 OTU The TC12 can be configured as one of two methods on the ST900. Th

Seite 54

Part Number 667-CC-32900-000 Issue 8 Page 58of 67 7.11.2 Free Standing TC12 OTU The Freestanding TC12 OTU will be installed in the a

Seite 55

Part Number 667-CC-32900-000 Issue 8 Page 59of 67 7.12 Loop termination PCBs The Loop Termination PCBs are contained within the Int

Seite 56

Part Number 667-CC-32900-000 Issue 8 Page 6 of 67 4 General Parts List 4.1 ST900ELV Configuration Parts Table 3 Part Number Des

Seite 57 - TC 12 OTU

Part Number 667-CC-32900-000 Issue 8 Page 60of 67 Figure 70 show the positioning of the loop termination PCB when serial I/O cards on

Seite 58

Part Number 667-CC-32900-000 Issue 8 Page 61of 67 Figure 71 show the positioning of the loop termination PCBs when serial I/O cards o

Seite 59 - Loop termination PCBs

Part Number 667-CC-32900-000 Issue 8 Page 62of 67 Flow chart LV Controller I/O and Loop termination PAC Allocation Rules Figure 72

Seite 60

Part Number 667-CC-32900-000 Issue 8 Page 63of 67 Figure 73 shows a Loop Termination PCB. PL2 on the Loop Termination PCB should be c

Seite 61

Part Number 667-CC-32900-000 Issue 8 Page 64of 67 Figure 74 7.14 Tactile Driver from Audible Supply Kit 667/1/27006/000 Tacti

Seite 62

Part Number 667-CC-32900-000 Issue 8 Page 65of 67 7.16 Detector Power Detector Power General With reference to figure 75 an addi

Seite 63

Part Number 667-CC-32900-000 Issue 8 Page 66of 67 Figure 75 1 2 3 4 5 6 7 9 11 12 10 8 15 14 13 Left Hand Mounting Panel Tran

Seite 64 - Regulatory Sign Kit

Part Number 667-CC-32900-000 Issue 8 Page 67of 67 7.17 SDE/SA PCB Kit 667/1/27005/000 SDE/SA is an integral facility in the ST900

Seite 65 - Detector Power

Part Number 667-CC-32900-000 Issue 8 Page 7 of 67 4.2 ST900 Configuration Parts Table 4 Part Number Description 667/1/33900/010 S

Seite 66 - 15 14 13

Part Number 667-CC-32900-000 Issue 8 Page 8 of 67 5 System overview of the ST900 Family 5.1 ST900 ELV overview The ST900 ELV C

Seite 67 - Solar Cell

Part Number 667-CC-32900-000 Issue 8 Page 9 of 67 6 ST900 ELV Hardware Allocation and Connectivity 6.1 ST900ELV Outercase Selecti

Kommentare zu diesen Handbüchern

Keine Kommentare