78 Series Electromechanical
Relay Specifications
781 Series Contact Ratings (current)
Resistive *Motor Load
Voltage Nominal UL CSA UL
28VDC 12A 12A 12A ---
120VAC 15A 15A 15A 1/2Hp
277VAC 12A 12A 12A 1Hp
782 Series Contact Ratings (current)
Resistive *Motor Load
Voltage Nominal UL CSA UL
28VDC 12A 12A 12A ---
120VAC 15A 15A 15A 1/2Hp
277VAC 12A 12A 12A 1Hp
NEMA Mechanical Switching Ratings and Test Values for AC Control Circuit Contacts
Contact Rating
Designation
Thermal Continuous
Test Current (A)
Maximum AC Current, 50/60Hz (A)
Voltamperes
120 Volts 240 Volts 480 Volts 600 Volts
Make Break Make Break Make Break Make Break Make Break
B300
5 30 3.00 15 1.50 --- --- --- --- 3600 360
This chart is provided as a guideline only, and the ratings and values are not guaranteed to be accurate. It is the users’ responsibility to properly size their control
circuit devices. The chart values are from NEMA Standard ICS 5-2000, Table 1-4-1.
78 Series Relay Specification Table
Part Numbers
781-1C-12D
781-1C-12A
781-1C-24D
781-1C-24A
781-1C-120A
781-1C-240A
782-2C-12D
782-2C-12A
782-2C-24D
782-2C-24A
782-2C-120A
782-2C-240A
General Specifications
*Service Life: Mechanical / Electrical Operations
Mechanical: 10,000,000 operations unpowered
Electrical: 100,000 operations @ rated resistive load
Operating Temperature
-40°C to 55°C (-40°F to 131°F)
Response Time
20ms
Ambient Humidity
45% RH to 85% RH
Vibration Resistance
3 G’s, 10 to 55Hz (0.6 mm double amplitude)
Shock Resistance
10 G’s
Weight
29g (1.02 oz) 36g (1.27 oz)
**Agency Approvals and Standards
UL Recognized File E191059, CE, CSA
Environmental Protection
IEC IP40
NEMA B300 Pilot Duty Rated
Yes
Coil Specifications
Standard
LED Indicator
Coil Input Voltage
12VDC
12VAC
50/60 Hz
24VDC
24VAC
50/60 Hz
120VAC
50/60 Hz
240VAC
50/60 Hz
12VDC
12VAC
50/60 Hz
24VDC
24VAC
50/60 Hz
120VAC
50/60 Hz
240VAC
50/60 Hz
Coil Resistance
188q 46q 750q 180q 4.43 kq 15.72 kq 160q 46q 650q 180q 4.43 kq 15.7 kq
Power Consumption
0.7 W DC,
0.9 VA @ 60Hz AC @ 25°C
0.9 W DC,
1.2 VA@ 60Hz AC @ 25°C
Dropout Voltage (% of nominal voltage or more)
10% 15% Min.10% Min. 15% 10% 15% Min. 10% Min. 15%
Pull-in Voltage (% of nominal voltage or less)
80% 85% 80% 85% 80% 85% 80% 85%
Max. Voltage (Max. continuous voltage)
110% of the rated coil voltage
Contact Specifications
Contact Type
SPDT DPDT
Contact Material
Silver cadmium oxide, gold flashed
Minimum Switching Requirement
100mA @ 5VDC
Max. Contact Rating
Refer to Contact Ratings charts.
Dielectric Strength Between Contacts
1500V rms
*Note: These devices are rated for 1,000 cycles when used in a motor application. (Per Table 45.1, UL 508).
**Note: UL listed when used with sockets 781-1C-SKT, 782-2C-SKT, 783-3C-SKT, 784-4C-SKT, or 784-4C-SKT-1.
Current limited to rating of relay or socket, whichever is less.
Kommentare zu diesen Handbüchern