Ordering data
1/17
SIPAN 32 and SIPAN 32X analyzers
1 signal output: 4 to 20 mA,
with HART interface B
Order No.
2 signal outputs
with HART interface:
1st signal output:
measured value 4 to 20 mA,
2nd signal output: temperature or
switching contact for limit or
cleaning or warning C
SIPAN 32 analyzer
Two-wire system,
for conductivity measurements
Measuring procedure:
Two-electrode procedure (2EL) 7MA2040-8A
Four-electrode procedure (4EL) 7MA2140-8A
Inductive procedure (IND) 7MA2240-8A
Microprocessor-based,
membrane keyboard with LCD,
menu control, logbook,
concentration display,
temperature compensation,
diagnostic software, 1 parameter set,
power supply: DC 24 V,
in field housing
Standard version,
1 signal output: 4 to 20 mA
without interface A
Isolating power supply
(see MP 19, Section 5
for technical data)
D With AC/DC 24 V power supply,
DIN rail mounting 7NG4121-1AA00-1NN0
D With AC/DC 24 V power supply,
PCB, individual locking 7NG4021-4CA33-0NN0
D With AC 115 V power supply,
DIN rail mounting 7NG4021-6BA33-0NN0
D With AC 230 V power supply,
DIN rail mounting 7NG4021-6AA33-0NN0
D HART version
with Ex protection EEx ia IIC, smart,
with AC/DC 24 V power supply,
compact subassembly,
DIN rail mounting 7NG4121-1AA20-1AN0
D HART version
with Ex protection EEx ia IIC, smart,
with AC/DC 24 V power supply,
PCB, individual locking 7NG4021-4CA33-2NA1
Order No.
Calibrated reference equipment See page 1/25
Order No.
1 signal output: 4 to 20 mA,
with HART interface B
Order No.
2 signal outputs
with HART interface:
1st signal output:
measured value 4 to 20 mA,
2nd signal output: temperature or
switching contact for limit or
cleaning or warning C
SIPAN 32X analyzer with Ex protection,
intrinsically-safe version,
II 2G EEx ia IIC T4,
two-wire system,
for conductivity measurements
Measuring procedure:
Two-electrode procedure (2EL) 7MA2041-8A
Four-electrode procedure (4EL) 7MA2141-8A
Inductive procedure (IND) 7MA2241-8A
Microprocessor-based,
membrane keyboard with LCD,
menu control, logbook,
concentration display,
temperature compensation,
diagnostic software, 1 parameter set,
power supply: DC 24 V,
in field housing
Standard version,
1 signal output: 4 to 20 mA
without interface A
Accessories/mounting material Order No.
For mounting of analyzer or isolating
power supply on a pipeline (see
page 1/28 for dimensional drawing)
Protective hood (mat. No. 1.4571)
with base plate C79451-A3177-D12
Pipe clamp (mat. No. 1.4571) 7MA8500-8DG
Base plate (mat. No. 1.4571) C79451-A3177-D11
Set of screwdrivers ”TORX” C79451-A3246-D50
Order No.
Handheld HART communicator
Intrinsically-safe version EEx ia IIC T4
(see MP 17, Section 5
for technical data)
D German version 7MF4998-8KF
D English version 7MF4998-8KT
HART modem 7MF4997-1DA
Software for PC On request