6/27
Siemens IK PI · 2015
■
Technical specifications (continued)
Industrial Wireless Communication
IWLAN – Access Points IEEE 802.11n
SCALANCE W788 M12 for indoor use
Product functions management,
configuration
Number of manageable IP addresses
in client
8 8
Product function
•CLI Yes Yes
• web-based management
Yes Yes
• MIB support
Yes Yes
• TRAPs via email
Yes Yes
• Configuration with STEP 7
in preparation in preparation
• configuration with STEP 7
in the TIA Portal
in preparation in preparation
• operation with IWLAN controller
No No
• operation with Enterasys WLAN
controller
No No
• forced roaming with IWLAN
Yes Yes
•WDS
Yes Yes
Protocol is supported
• Address Resolution Protocol (ARP) Yes Yes
•ICMP
Yes Yes
• Telnet
Yes Yes
• HTTP
Yes Yes
• HTTPS
Yes Yes
• TFTP
Yes Yes
•SNMP v1
Yes Yes
•SNMP v2
Yes Yes
•SNMP v3
Yes Yes
•DCP
Yes Yes
• LLDP
Yes Yes
Identification & maintenance function
• I&M0 - device-specific information Yes Yes
• I&M1 – higher level designation/
location designation
Yes Yes
Product functions Diagnosis
Product function
• PROFINET IO diagnosis in preparation in preparation
• localization via Aeroscout
in preparation in preparation
• SysLog
Yes Yes
Product functions VLAN
Product function function VLAN with
IWLAN
Yes Yes
Product functions DHCP
Product function
• DHCP client Yes Yes
• in Client Mode DHCP server
via LAN
No No
Product functions Redundancy
Protocol is supported STP/RSTP Yes Yes
1)
Wireless approval in the USA
Article No. 6GK5788-1GD00-0AA0 6GK5788-2GD00-0AA0
6GK5788-1GD00-0AB0
1)
6GK5788-2GD00-0AB0
1)
Product-type designation SCALANCE W788-1 M12 SCALANCE W788-2 M12
Kap_06_IWC_en.book Seite 27 Dienstag, 7. Oktober 2014 1:47 13
© Siemens AG 2014