LIQUID APPLICATIONS - STANDPIPES
In many applications access must be made via a standpipe. In such cases, Milltronics can
provide factory bonded flanged transducers or split flange kit that will readily mate to the
flanged standpipe. Another option is to hang the transducer from a blind flange.
The standpipe length should be as short and the diameter as large as possible. As a rule of
thumb, the -3 dB cone of the sound beam should not intersect the standpipe wall in
applications opening into a vessel or larger area. Otherwise, additional blanking will be
required to compensate for the interference zone created by the opening.
flanged
transducer
vessel
no additional blanking required
no
intersection
vessel
nipple welded into
blind flange
transducer
sound beam
intersects
no vessel
no additional blanking required
near blanking extension
of 150 mm (6") past end of
standpipe may be required.
reflection at
interference zone
created by opening
no additional blanking required
nipple welded into
a blind flange
transducer
transducer
can read
level inside
or below
standpipe
standpipe
end cut on a
45 ° angle
typically
Note: When using a stilling well, make sure there is no build-up, welds, couplings, or other
debris on the inside of the well wall. This can affect reliability of level measurement.