
SOLIDS APPLICATIONS - TYPICAL
3. Transducer too close to material
inlet. Falling material will intersect
sound beam and cause erroneous
readings or loss of echo.
1. Transducer angled to avoid
seams in bin wall and aimed at
discharge in order to read bin
when empty.
2. Avoid intersecting bin wall
seams, structural members and
wall irregularities. Otherwise,
5. On dual discharge bins, aim each
transducer at the discharge point.
4. On fluid like solids, aim
transducer perpendicular to
material surface.
Easy Aimer
bin wall seams
filling profile
emptying profile
transducer
minimal angle
of repose
discharge
1
2
3
4
5
7ML19981AK01.2 XPS/XCT Transducers 17
Kommentare zu diesen Handbüchern