Siemens SIMATIC TI505 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Gateways / Controller Siemens SIMATIC TI505 herunter. Siemens SIMATIC TI505 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 22
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Simatic/TI 505 Serial
Driver Help
© 2012 Kepware Technologies
Seitenansicht 0
1 2 3 4 5 6 ... 21 22

Inhaltsverzeichnis

Seite 1 - Driver Help

Simatic/TI 505 SerialDriver Help© 2012 Kepware Technologies

Seite 2 - Table of Contents

Simatic/TI 505 Serial Driver HelpDP Slave channels if present. STW027 is slave1…STW138 is slave 112.Bit range is the same as for STW011.STW00139 This

Seite 3 - Overview

Simatic/TI 505 Serial Driver HelpBit 13, 1 = Attempt to invoke restricted specialfunction program or subroutine.STW00163 Contains the number of the la

Seite 4 - Addressing Options

Simatic/TI 505 Serial Driver HelpBit 3, 1 = First Run Mode scan after transitionfrom Hold Mode.Bit 9, 1 = First scan after battery bad power-uprestart

Seite 5 - Bit Order for V, K, STW

Simatic/TI 505 Serial Driver HelpSTW0231 Profibus DP I/O Status.Bit 1, 1 = DP in operate state.Bit 2, 1 = DP in clear state.Bit 3, 1 = Error: Unable t

Seite 6 - Data Types Description

Simatic/TI 505 Serial Driver Helpstopped communicating with the remote base dueto communications errors or response timeouts.STW 471 corresponds to re

Seite 7 - NITP Addressing

Simatic/TI 505 Serial Driver HelpError DescriptionsThe following error/warning messages may be generated. Click on the link for a description of the m

Seite 8 - Status Words

Simatic/TI 505 Serial Driver HelpSolution:Re-enter the address in the client application.Address '<address>' is out of range for the s

Seite 9

Simatic/TI 505 Serial Driver HelpSerial CommunicationsCOMn does not existError opening COMnCOMn is in use by another applicationUnable to set comm par

Seite 10

Simatic/TI 505 Serial Driver HelpT = TX buffer full.Possible Cause:1. The serial connection between the device and the host PC is bad.2. The communica

Seite 11

Simatic/TI 505 Serial Driver Help2. The location is read only in the device.3. The device could not perform the write operation.Solution:Refer to the

Seite 12

Simatic/TI 505 Serial Driver HelpTable of ContentsTable of Contents 2Simatic/TI 505 Serial Driver Help 3Overview 3Device Setup 4Modem Setup 4Addressin

Seite 13

Simatic/TI 505 Serial Driver HelpIndexAAddress Descriptions7Address Validation15Addressing Options4Array size is out of range for address '<ad

Seite 14

Simatic/TI 505 Serial Driver HelpFraming17LLong6MMask17Missing address15Modem Setup4NNetwork4NITP Addressing7OOverrun17Overview3PParity17SSerial Commu

Seite 15

Simatic/TI 505 Serial Driver HelpUUnable to read block starting at <address> for device <device name>:Error code <code>19Unable to s

Seite 16

Simatic/TI 505 Serial Driver HelpSimatic/TI 505 Serial Driver HelpHelp version 1.019CONTENTSOverviewWhat is the Simatic/TI 505 Serial Driver?Device Se

Seite 17

Simatic/TI 505 Serial Driver HelpDevice SetupSupported DevicesTI Series 500/505 processors: 520, 525, 535, 545, 555, 565 and 575.Communication Protoco

Seite 18

Simatic/TI 505 Serial Driver HelpMemory types that allow bit within Word (for example, V) can be referenced as a Boolean. The addressingnotation for d

Seite 19

Simatic/TI 505 Serial Driver HelpData Types DescriptionData Type DescriptionBoolean Single bitWord Unsigned 16 bit valuebit 0 is the low bitbit 15 is

Seite 20

Simatic/TI 505 Serial Driver HelpAddress DescriptionsAddress specifications vary depending on the model in use. Select a link from the following list

Seite 21

Simatic/TI 505 Serial Driver HelpTransparent Byte AddressingThe Simatic/TI 505 Serial driver supports the following addresses when using the Tranparen

Seite 22

Simatic/TI 505 Serial Driver HelpRegister Description CP525 CP545 CP565 CTI 2500STW00001 Non-Fatal Errors.Bit 4, 1 = Password has been entered.Bit 5,

Kommentare zu diesen Handbüchern

Keine Kommentare