Simatic / TI 505Ethernet Driver Help© 2015 Kepware Technologies
Simatic/TI 505 Ethernet Driver HelpEach device has now been defined under its own channel. Inthis new configuration, a single path of execution isdedi
Simatic/TI 505 Ethernet Driver HelpData Types DescriptionData Type DescriptionBoolean Single bitWord Unsigned 16-bit valuebit 0 is the low bitbit 15 i
Simatic/TI 505 Ethernet Driver HelpAddress DescriptionsAddress specifications vary depending on the model in use. Select a link from the following lis
Simatic/TI 505 Ethernet Driver HelpV-Word MemoryBCD DecimalV<address>B 1-167772151-16777214Short, Word,BCDLong, DWord,FloatRead/WriteV-Word Memo
Simatic/TI 505 Ethernet Driver HelpDWord, FloatSystem StatusBit AccessSTW<address>.<bit>STW<address>:<bit>STW<address>,&
Simatic/TI 505 Ethernet Driver HelpThis type of string is a Standard String with LoHi byte order except the string length is always the maximumbecause
Simatic/TI 505 Ethernet Driver HelpNote: All 10 characters are displayed with the null-terminated string "hello" padded with 5 spaces to fil
Simatic/TI 505 Ethernet Driver Help0 = Status is good.1 = Base is not present or has a problem.Bit 1, Base 15Bit 2, Base 14Bit 3, Base 13Bit 4, Base 1
Simatic/TI 505 Ethernet Driver HelpBit 9-12, Seconds - Tens digitBit 13-16, Seconds - Units digitSTW144 Bit 1-4, Seconds - Tenths digitBit 5-8, Second
Simatic/TI 505 Ethernet Driver Help1 = Error or single power supplySTW00177-00183 Not used x x x xSTW00184 Module Mismatch IndicatorBit 1, 1 = Module
Simatic/TI 505 Ethernet Driver HelpTable of ContentsTable of Contents 2Simatic / TI 505 Ethernet Driver Help 3Overview 3Device Setup 4Cable Diagrams 5
Simatic/TI 505 Ethernet Driver HelpSTW213 Bit 1-16 slave addresses 48-33STW214 Bit 1-16 slave addresses 64-49STW215 Bit 1-16 slave addresses 80-65STW2
Simatic/TI 505 Ethernet Driver HelpChecksumSTW00243 Reserved N/A N/A N/A xSTW00244 Additional Control Status FlagsBit 1, Controller Mode 0 = Program M
Simatic/TI 505 Ethernet Driver HelpNote: The actual number of addresses available for of each type depends on the PLC's configuration. If the dri
Simatic/TI 505 Ethernet Driver HelpAlarm MSW AlarmC FlagsACFH<address> 1-65536 Word Read/WriteAlarm LSW AlarmC FlagsACFL<address> 1-65536
Simatic/TI 505 Ethernet Driver HelpP 15/16, 0/1 Not used, set to 0*Elements A and B are write-only triggers. Writing 1 to the triggers sets the mode.
Simatic/TI 505 Ethernet Driver Helpe 30/31, 1/2 Contains SF program number (if an SF program is scheduled to be called)f 31/32, 0/1 Contains SF progra
Simatic/TI 505 Ethernet Driver HelpLoop Raw Setpoint LSPR<address> 1-65536 Word Read/WriteLoop Raw Error LERRR<address> 1-65536 Word Read
Simatic/TI 505 Ethernet Driver HelpElement LVF bit DescriptionA 0/1, 15/16 1=Go to manual mode*B 1/2, 14/15 1=Go to auto mode*C 2/3, 13/14 1=Go to cas
Simatic/TI 505 Ethernet Driver HelpL 11/12,20/211=Auto-mode lockM 12/13,19/201=Cascade-mode lockN 13/14,18/191=Setpoint lockO 14/15,17/180=Output scal
Simatic/TI 505 Ethernet Driver Help12/13E 4/5,11/121=Wait. This bit is set during a soak period when the PV is not within a specifieddeviation from th
Simatic/TI 505 Ethernet Driver HelpSimatic / TI 505 Ethernet Driver HelpHelp version 1.037CONTENTSOverviewWhat is the Simatic / TI 505 Ethernet Driver
Simatic/TI 505 Ethernet Driver Helpenough addresses are found to fill the output buffer. The search will cycle through all address types (C then X/Yfo
Simatic/TI 505 Ethernet Driver HelpError DescriptionsThe following messages may be generated. Click on the link for a description of the message.Addre
Simatic/TI 505 Ethernet Driver HelpData type <type> is not valid for device address <address>.Error Type:WarningPossible Cause:A tag addre
Simatic/TI 505 Ethernet Driver HelpSolution:Check network connections.Device <device name> detected a Task Code error <error> (tag <add
Simatic/TI 505 Ethernet Driver HelpPossible Cause:The device is unable to receive the amount of write data sent in one request.Note:This error is used
Simatic/TI 505 Ethernet Driver HelpPossible Cause:The version number of the Winsock DLL found on the system is less than 1.1.Solution:Upgrade Winsock
Simatic/TI 505 Ethernet Driver HelpTask Code Error CodesCode Description02 Address out of range (other than ladder logic).03 Requested data not found.
Simatic/TI 505 Ethernet Driver HelpIndex5505 Protocol 6AACF Bit Definitions 24Address <address> is out of range for the specified device or regi
Simatic/TI 505 Ethernet Driver HelpFFind Forced Addressing 29Float 11LLCF Bit Definitions 27Long 11Loop Addressing 25LRSF Bit Definitions 28LVF Bit De
Simatic/TI 505 Ethernet Driver HelpWWinsock initialization failed (OS Error = n). 34Winsock V1.1 or higher must be installed to use the Simatic/TI 505
Simatic/TI 505 Ethernet Driver HelpDevice SetupSupported DevicesCTI Interface CardsCTI 2572, CTI 2572-A, and CP2572 Ethernet interface cards on TI ser
Simatic/TI 505 Ethernet Driver HelpCable DiagramsCommunications Parameterswww. kepware.com5
Simatic/TI 505 Ethernet Driver HelpDescriptions of the parameters are as follows:l Port Number: This parameter specifies the port number that the remo
Simatic/TI 505 Ethernet Driver HelpFor applications where the data can be divided into large blocks, using CAMP memory transfer will result in themost
Simatic/TI 505 Ethernet Driver HelpBit Order for V, K, WX, WY and STWThis option is used to select the order in which bits will be presented to V, K,
Simatic/TI 505 Ethernet Driver HelpOptimizing Simatic / TI 505 Ethernet CommunicationsThe Simatic / TI 505 Ethernet driver has been designed to provid