onditional programming ensures appropriate responses are given to alarms, on site and remotely.
Clear system overviews ensure total control at all times
Direct alarm management
The type of alarms generated by the SPC
systems can vary depending on the type
of zone that triggered the alarm activa-
tion (Each zone type will activate its own
unique output type an internal flag or
indicator that can then be logged or
assigned to a physical output for activa-
tion of a specific device).
A Full Alarm activation will report the
alarm to the Alarm Receiving Centre
(ARC) if one has been configured.
A Local Alarm activation will not
attempt to call the ARC even if one has
already been configured.
A Silent Alarm activation will not
generate any visual or audible indica-
tions of the alarm. The alarm event
will be reported to the ARC.
Versatile alarm verification
The SPC series enable several events to
be filtered before the alarm is transmit-
ted. The alarm transmission can also
either be delayed or confirmed to prevent
unnecessary intervention costs.
Event logs
Up to 10,000 intrusion and 10,000 access
events can be logged depending on the
controller model. The event log can be
accessed via the keypad and displayed
on the LCD screen, either as a list of the
most recent events, or by doing a date/
time search.
Safer alarm handling
The SPC Com alarm receiver software
(SPC6000 via alarm over IP) provides a
graphical status representation of all SPC
Highlights
Pre-defined operation modes facilitate
set-up and reduce operator error
Comprehensive system set options
Local or remote system control
Zone-specific alarm activation and
transmission types
Alarm transmission delay functionality
with verification through event filtering
Optimal queued alarms transmission
in one call
Separate intrusion and access
event logs
Graphical system alarm status
Log of alarm responses and procedures
panels connected to the system. This
enables a quicker event investigation and
intervention. Actions undertaken in
response to alarms can be logged for future
reference, and response procedures can
also be displayed to guide the user through
the appropriate alarm handling steps.