05.07 DNC Plant/DNC Cell (FBDN1)
10 Configuration
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
FBDN1/10-173
COM interface
The COM interface is used for connecting the machine. Interfaces 1 to 256 can
be assigned.
1= COM1
....
16= COM256
Extract from machine configuration file:
[COM]
ComPort = 2
Note
ComPort=0 is not a valid interface.
Baud rate
The baud rate specifies the transmission rate of the interface.
Baud rates of 110 to 256000 are possible.
Extract from machine configuration file:
BaudRate = 9600
Number of data bits
6, 7 or 8 bits can be evaluated as data bits.
Extract from machine configuration file:
ByteSize = 8
Number of stop bits
1 or 2 bits can be evaluated as stop bits.
Extract from machine configuration file:
StopBits = 1
Parity
The following parities can be defined:
Table 10-3: Parity of the serial interface
N=No No parity check
O=Odd Odd parity
E=Even Even parity
M=Mark Logical 1
S=Space Logical 2
Extract from machine configuration file:
Parity = N