Siemens ET 78X Series Betriebsanleitung Seite 328

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 349
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 327
DNC IFC SINUMERIK - Downloading NC Data via a Network (FBDN2) 05.07
5 Configuration file
© Siemens AG 2010 All Rights Reserved
FBDN2/5-46 Motion Control Information System DNC (FBDN) - 04/10 Edition
MSDE / SQL server instance
The entry field is only relevant and sensitive for MSDE databases. The instance of
the MSDE database (SQL Express) must be entered in the entry field. If no
instance has been assigned for the database, the field must remain empty.
Extract from the configuration file:
[SQLSERVER]
INSTANCE=MCIS
DCOM
Domain, user name and password on the DNC server are defined in the entry
fields at the top right for the DCOM connection.
Extract from the configuration file:
Section[DCOM]
DOMAIN =DNC_Dom
USER = John Do
PASSWORD =******
Remote login
The definitions for the domain, user name and password of the DCOM connection
are also used for the remote login when this checkbox is activated.
Extract from the configuration file:
[REMOTELOGIN]
REMOTELOGIN=1
Machine
Machine is for the assignment to a machine (controller) configured in DNC. The
machine name of the machine assigned in DNC is entered in the Machine entry
field.
Extract from the configuration file:
Section[MACHINE]
Machine = PCU50_840D
Seitenansicht 327