05.07 DNC Plant/DNC Cell (FBDN1)
10 Configuration
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
FBDN1/10-195
[DIALOGFUNCTION]
;---DlgScanLines---: (number of the signifcant lines, beginning with line 1)
DlgScanLines=10
;---Parameters in special ASCII-Character- Words---
;---DlgID---: (Name of the dialogue file)
DlgID=%MPF9999
;---DlgIDSend---: (Name of the answer file (list, error), sent from DNC_NT to
machine)
DlgIDSend=%MPF9998
;---DlgSendEnd---: (Program End for the answer file (list, error), sent from DNC_NT
to machine)
DlgSendEnd=M30
;---DlgSendCmd---: (character which indicades to download a file with releaseID)
DlgSendCmd=(S)
;---DlgSendTcCmd---: (character which indicades to download a file with trialcutID)
DlgSendTcCmd=(ST)
;---DlgReceiveCmd---: ( character which indicades to upload a file from machine to
DNC)
DlgReceiveCmd=(R)
;---DlgSendListCmd---: ( character which indicades to download a filelist of the
machinedirectory in DNC)
DlgSendListCmd=(SL)
;---DlgWpdMark---: (allows to change the shortcut of an workpiece directory)
DlgWpdMark=WPD
;if it is impossible to write MPF, SPF, TOA ... you can define a character followed
by a number
;Y001 = MPF, Y002 = SPF, Y003 = TOA ... ordernumber as defined in Databasetable
NCDATATYPE
DlgExchangeCNCType=
;in exchange for * if it is impossible to write *, eg. X999 (only for use with
DlgSendListCmd!)
DlgExchangeWildcard=
;DlgConverter=DNCDlgI.DNCCntrl
DlgConverter=
DlgSubNumber=0
;CutFromName=
;------- The following parameters are directly corresponding to MiniDNC -------------
--------------
;
;MiniDNC DNC_NT-2000
;#####################################
; [COM]
; #1210 [COM] XONChar
; #1211 [COM] XOFFChar
; #1401 [COM] ComPort, or Paramter: [SEND] SendBaudRate
; #1402 [COM] FlowCtrl,
; #1403 [COM] BaudRate, Parity, ByteSize, StopBits
; #1501 [COM] ComPort,
; #1502 [COM] FlowCtrl,
; #1503 [COM] BaudRate, Parity, ByteSize, StopBits
; not existent [COM] binary
; [SEND]
; #1201 [SEND] ProgramStart
; #1202 [SEND] ProgramEnd
; not existent [SEND] CommentStart
; not existent [SEND] CommentEnd
; #1205 [SEND] HeaderChar
; #1207 [SEND] TrailerChar
; #1204 [SEND] HeaderSize
; #1206 [SEND] TrailerSize
; #1209 [SEND] SpacerChar
; #1208 [SEND] SpacerSize
; not existent [SEND] SkipFirstSpacerMark
; #1217 [SEND] SpacerMark1
; #1218 [SEND] SpacerMark2
; #1219 [SEND] SpacerMark3
; #1220 [SEND] SpacerMarkInsertAfter1
; not existent [SEND] SpacerMarkInsertAfter2
; not existent [SEND] SpacerMarkInsertAfter3
; #1203 [SEND] EOBcode
; not existent [SEND] SuppressComment
; #1103 [SEND] SendTimeout
; #1401 [SEND] SendBaudRate
Kommentare zu diesen Handbüchern