Siemens ET 78X Series Betriebsanleitung Seite 212

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 349
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 211
DNC Plant/DNC Cell (FBDN1) 05.07
10 Configuration
© Siemens AG 2010 All Rights Reserved
FBDN1/10-204 Motion Control Information System DNC (FBDN) - 04/10 Edition
Pseudo workpiece
If you want to compare the data from a selected DM directory with a pseudo
workpiece called name.DIR or archive it in a pseudo workpiece, you have to
activate this checkbox.
Note
If you activate the Pseudo Workpiece checkbox here, it will also be taken into
account when data is uploaded.
If DNC IFC SINUMERIK is also installed on the relevant machine, the pseudo
workpiece ID must be set during configuration for the same data
management directories.
0: No pseudo workpiece
1: Pseudo workpiece
Data types
In this field, you specify the data types for the selected directory that are to be
taken into account when comparisons are carried out and when data is
archived.
Exclude file
If files should be excluded from the comparison and the archiving, this should
be specified in the Exclude file file.
For example, EXCLUDE_MPF.DIR =Test1
Extract from the machine configuration file:
For example, WKS.DIR directory, (no pseudo workpiece), files of the type
MPF, SPF, TOA, etc., will be considered, the WKSA1 file will be excluded
DHDIR1 = WKS.DIR;0;MPF;SPF;TOA;ZOA;RPA;WPL;JOB;BMP;ARC;INI
EXCLUDE_WKS.DIR =WKSA1
Seitenansicht 211
1 2 ... 207 208 209 210 211 212 213 214 215 216 217 ... 348 349

Kommentare zu diesen Handbüchern

Keine Kommentare