Siemens XPS15F Bedienerhandbuch Seite 1

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Nein Siemens XPS15F herunter. Siemens XPS15F Instruction manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - XPS/XCTTRANSDUCERS

XPS/XCT SERIESTRANSDUCERSXPS/XCTTRANSDUCERSInstruction Manual December 2001

Seite 2 - Disclaimer of Liability

INTERCONNECTIONFor EnviroRangerERS 500 only,connect all threewires separately.When connecting to an EnviroRanger ERS 500, do NOT use coaxialcable, us

Seite 3 - ABOUT THE TRANSDUCER

DO’S AND DON’TSInstallation shall only be performed by qualified personnel and in accordance with local governing regulations.Do not route cable openl

Seite 4 - SIRA 01ATEX5262X

APPLICATIONS The transducer is to be used only in the manner outlined in this instruction manual.Normally, the transducer requires no cleaning or mai

Seite 5 - SPECIFICATIONS

LIQUID APPLICATIONS - SUBMERGENCEIn applications where flooding is possible the transducer▼ can be fitted with a submergenceshield. The shield acts a

Seite 6 - * nominal

LIQUID APPLICATIONS - STANDPIPESIn many applications access must be made via a standpipe. In such cases, Milltronics canprovide factory bonded flanged

Seite 7 - (typical model)

LIQUID APPLICATIONS - VOLUME1. Beam should not detect bin bottom. If this occurs use range extension parameters (on transceivers where available) to o

Seite 8 - Submersible

LIQUID APPLICATIONS - WATER / WASTEWATERDIFFERENTIAL LEVELPUMP CONTROLSEWAGE LIFT16 XPS/XCT Transducers 7ML19981AK01.2

Seite 9

SOLIDS APPLICATIONS - TYPICAL3. Transducer too close to material inlet. Falling material will intersect sound beam and cause erroneous rea

Seite 10 - Coaxial Extension

SOLIDS APPLICATIONS - SPECIALSTORAGE BIN WITH AGITATOR1. Transducer should be kept away from infeed.2. Where agitators are in use, use the Agitator Di

Seite 11 - DO’S AND DON’TS

INSTALLATION DIAGRAM See Milltronics drawing number 0-9650017Z-DI-A for current drawing status.7ML19981AK01.2 XPS/XCT Transducers 19

Seite 12 - APPLICATIONS

© Siemens Milltronics Process Instruments Inc. 2001Safety GuidelinesWarning notices must be observed to ensure personal safety as well as that of oth

Seite 13 - on applicable models

FOR CANADIAN HAZARDOUS INSTALLATIONS ONLYSee Milltronics drawing number 0-8850004Z-DI-A for current drawing status.20 XPS/XCT Transducers 7ML19981AK01

Seite 14

NotesNotes.fm Page 2 Thursday, October 11, 2001 8:48 AM

Seite 15 - LIQUID APPLICATIONS - VOLUME

NotesNotes.fm Page 1 Thursday, October 11, 2001 8:48 AM

Seite 16 - DIFFERENTIAL LEVEL

IQ300IX.fm Page 5 Tuesday, October 2, 2001 1:43 PM

Seite 18 - SOLIDS APPLICATIONS - SPECIAL

ABOUT THE TRANSDUCERThe Echomax XPS / XCT series of transducers operates in association with Milltronics ultrasonic level monitoring products.The tran

Seite 19 - INSTALLATION DIAGRAM

XPS D Series - Certificate SIRA 01ATEX5262XThis equipment may be used in all hazardous dust zones with all conductive andnon-conductive dusts. The Typ

Seite 20

7ML19981AK01.2 XPS/XCT Transducers 5SPECIFICATIONSModel :XPS - 10 XPS - 15 XPS - 30 XPS - 40 XCT - 8 XCT - 12MeasurementRange,0.3 - 10 0.3 - 15 0.6 -

Seite 21

OUTLINE AND DIMENSIONSradiating faceoptional submergence shieldrefer to associated instructionsoptional bonded flangerefer to associated instructionss

Seite 22

MOUNTINGDO’S AND DON’TSSpecial handling precautions must be taken to protect the face of the transducer from anydamage.Mount the transducer so that it

Seite 23

MOUNTING - LIQUID APPLICATIONSFlexible ConduitBracketSubmersiblePlywoodrigid metal conduitcouplingtransducersafetychainflexibleconduitsteel channelcou

Seite 24 - *7ml19981ak01*

MOUNTING - LIQUID APPLICATIONS (cont’d)nipple welded to blind flangecustomer flange, flat face onlyfactory flanged transducerboltgasketnutcouplingCust