How to configure an Anybus PROFIBUS Slave module with a Siemens Step7 PLC
SCM-7032-026
Rev 2.1
Open up the “Anybus-S PDP” entry in the hardware catalogue and drag and drop the Anybus module on to
the network, see description in Figure 11.
Figure 11 Drag and drop the Anybus module to the network.
It is then necessary to configure the Anybus module itself. The only configuring to be done is setting up the
node address, input and output data area sizes and offset address.
In Figure 12 it is shown how to edit the node address. The edit-window for the node address is opened by
doing the click sequence n, o, p. At p it is possible to set the desired node address. The address set here
must equal the address set on the Anybus-S module, see the chapter 1.1 Anybus module setting.
Figure 12 Adjusting the node address in HW Config.