Recording configuration
123
Siemens Building Technologies
Fire Safety & Security Products 03.2009
You have the following setting options in the recording modes:
Fig. 117 Control elements on the Recording tab
Setting Function Note
Pre-trigger
Duration
The period prior to an event (movement,
alarm or software trigger) which is
recorded after the event occurs.
Only available
z in the recording modes motion, alarm input,
priority alarm and software trigger
z if long-time recording is not enabled for all time
segments
z if the Single shot checkbox is not marked.
Pre-trigger / long-
time recording
Frame rate
The frame rate at which the pre-alarm
and long-time recording is to be saved.
Applies to all recording modes of a camera; it
cannot be set differently for the various recording
modes.
Software trigger We recommend setting the frame
rate of cash box cameras to 2.0/s.
Track length
limitation
The limitation of the hard drive capacity
taken up by a camera. The
SISTORE MX NVS software checks the
total recording duration of the camera
every hour; if it exceeds the track length
duration, older recordings for this
camera will be overwritten.
Write-protected recordings will not be overwritten
and can thus be longer than the track length
limitation setting.
Use the track length limitation if you want to
prioritize cameras: limit the recording duration of
less important cameras in order to keep more
hard drive capacity free for more important
cameras.
Post-trigger
Duration
The period which is recorded after an
event.
Only available
z in the recording modes motion, alarm input,
priority alarm and software trigger
z if the Single shot checkbox is not marked.
If another event is detected during the post-trigger
period, it is extended by the value set.
At least 10 frames will always be recorded.
The post-trigger period can also be controlled via
software (such as IVM); in this case, the software
control settings take priority over the settings of
the SISTORE MX NVS software.