9.3 Defining the detection area (mask)
You can define a detection area for LAN cameras. Select the LAN cameras tab in
the SISTORE MX NVS application software.
You have two options to define a detection area for sabotage detection:
z Draw detection area
z Copy detection area (save and load)
Draw detection area
Fig. 57 Mask (= detection area) group field in the SISTORE MX sabotage
detection dialog
Fig. 58 Drawing group field in the SISTORE MX sabotage detection dialog
Prerequisite
z The SISTORE MX sabotage detection dialog is opened.
See Section "
1017HConfiguring tamper detection", page 1018H64.
1. Mark the checkbox Mask.
Î The Mask (= detection area) group field will be activated.
2. Select a drawing colour from the Color… selection field.
3. Click the Pencil tool
radio button.
4. Select a shape tool in the Tool line.
5. If you have chosen the shape tool Line
:
Select the line width.
6. Draw the detection area in the live image of the camera.
7. Click OK.
Î The setting will be saved.
Tip: The eraser tool
allows you to correct the detection area. All the shape
tools can be used together with the eraser tool.