Configuring alarm inputs
75
Siemens Building Technologies
Fire Safety & Security Products 03.2009
Names can be up to 16 characters long.
4. Enter a short description, such as information on the position, in the Description
text field.
5. In the alarm input field, select the number of the physical device input (the
trigger input of the I/O card).
6. Click Apply.
Î The settings will be saved.
Deleting an alarm input
1. Select the Alarm input tab.
2. Select the alarm input you want to delete in the list.
3. Click the Delete alarm input button
.
4. Answer Yes in the confirmation dialog.
5. Click Apply.
Î Your settings will be saved.
11.2 Configuring USB alarm inputs
11.2.1 Trigger edge
NOTE:
The trigger edge applies to all alarm inputs. It cannot be set differently for multiple alarm inputs.
With the trigger edge you can determine whether
z an alarm input normally carries voltage and the voltage is interrupted during an
alarm (
)
z or an alarm input carries voltage only in the case of an alarm and otherwise not
(
).
The level sensitive checkbox allows you to determine whether a recording ends
directly after an edge or continues until the next edge.
Example:
The SISTORE MX NVS should start recording when a door is opened and stop
when the door closes. The door opener (alarm input) generates a short signal
(level change / edge) upon opening and closing of the door. If the level sensitive
checkbox is not marked, the SISTORE MX NVS records only short sequences
when the door is opened and when it is closed. If the checkbox is marked, the
SISTORE MX NVS records a longer sequence from when the door opens until it is
closed.
Fig. 64 Trigger edge (global) group field on the Alarm input tab
Fig. 65 Level sensitive checkbox on the Alarm input tab