Fig. 195 SISTORE RemoteView – configuration option for the server
Î The configuration file will be transferred from the server and saved in the
download directory.
Î SISTORE RemoteView will switch to configuration mode.
Î The file will be opened automatically.
4. Change the configuration.
5. Click Apply.
6. Answer Yes in the confirmation dialog.
Fig. 196 SISTORE RemoteView – sending the server configuration
Î The transmission will be performed.
Î After receiving the configuration, the server will import and apply it.
Recording will be stopped for a few seconds. The connection to RemoteView will be terminated.
7. Check whether the server is recording again and everything is running properly.
Î The transfer of a new configuration is recorded as information in the server's
logbook. The logbook will also indicate whether the server has accepted and
applied the new configuration.
z If a configuration contains more cameras than are available on the recording system, only the first
cameras of the configuration will be applied. All further cameras will be ignored.
z This also applies for objects that are in a configuration but are not physically present in the
recording system.
z Settings which cannot be configured remotely, such as recording drives, network settings or
deleting or adding LAN cameras, will not be applied by the server from the new configuration. For
these parameters the existing settings will continue to be used. This is to avoid malfunctions.
A malfunctions may result in a server restart triggered by the Watchdog. The malfunction will possibly
be corrected by the restart.
Restarting the server manually via SISTORE RemoteView
If the server can be reached by remote data transfer, it can be restarted via the