Simatic/TI 505 Ethernet Driver Help
1 = Error or single power supply
STW00177-00183 Not used x x x x
STW00184 Module Mismatch Indicator
Bit 1, 1 = Module mismatch error
Bit 5-8 = Indicates the number of the base with
the error
x x x x
STW00185-00190 Not used x x x x
STW00191 Serial Port Print Status N/A N/A N/A x
STW00192 Discrete Execution Scan Time - The time spent on
the last scan
x x x x
STW00193-199 Not used x x x x
STW00200 User Program Error Cause (associated with Bit 6 of
STW001). Codes are as follows:
0 = No error
1 = Reference to an application that is not
installed***
2 = Attempted to unlock a flag that is not held by
an application***
3 = Mismatched lock/unlock instructions***
4 = Subroutine nesting level exceeded
5 = Table overflow
6 = Attempted to call a non-existent subroutine
7 = VMEbus access failed due to a bus error***
8 = Special function program has not been
compiled or does not exist
9 = Special function program has been disabled
10 = Special function program type is restricted or
cyclic
11 = Special function program or subroutine is
being edited
12 = Special function program or subroutine is
being executed by an interrupt task
13 = User-scheduled fast loop is not configured
14 = User-scheduled fast loop is disabled
x x x x
STW00201 First Scan Flags
Bit 1, 1 = First Run Mode scan or single scan after
compile
Bit 2, 1 = First Run Mode scan or single scan after
Program Mode
Bit 3, 1 = First Run Mode scan after transition from
Hold Mode
Bit 9, 1 = First scan after battery bad power-up
restart
Bit 10, 1 = First scan after battery good power-up
restart
Bit 11, 1 = First scan after compile restart
Bit 12, 1 = First scan after partial restart
x x x x
STW00202-00205 Not used x x x x
STW00206-00207 U-Memory checksum C0 (32-bit integer) x x x N/A
STW00208-00209 U-Memory Checksum C1 (32 bit integer) x x x N/A
STW00210 Base Poll Enable Flags
Bit 1-16 are bases 15-0
For each Bit:
0 = Base cannot be polled
1 = Base can be polled
x x x x
STW00211-00217 Profibus Poll Enable Flags
Each bit is 1 if the slave is defined and enabled.
STW211 Bit 1-16 slave addresses 16-1
STW212 Bit 1-16 slave addresses 32-17
x x x x
www. kepware.com